| 2020-08-10 07:39:41 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20010941 |
| | ADD: 5300 45TH ST. |
| | CONT: TBD / TO BE DETERMINED |
| | TEL: 856-6655 / CONTACT: NEYITA LEIVA |
| | E-MAIL: NEYITA@/PS01.NET |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 5TH REVIEW |
| | DATE: MON. AUGUST 10TH/ 2020 |
| | ACTION: BUILDING PROVISOS |
| | |
| | 1) BUILDING PROVISO: ONCE THE PROPOSED SITE IS |
| | ACQUIRED, THE DEVELOPER WILL CONTACT ADDRESSING TECH. |
| | CAROLINE PUELL TO NOTIFY ALL INTERESTED PARTIES |
| | (POLICE, FIRE, UTILITIES, PALM BEACH COUNTY ADDRESSING, |
| | U. S. MAIL ? OF THE CHANGE OF ADDRESS FOR THIS SITE. |
| | |
| | 2) BUILDING PROVISO: A SEPARATE PERMIT IS REQUIRED FOR |
| | THE WALK IN COOLER/ FREEZER. SEPARATE REVIEW AND |
| | ASSOCIATED FEES. |
| | |
| | 3) BUILDING PROVISO: REVISION REQUIRED. DRINKING |
| | FOUNTAINS. THE LAST TELEPHONE CONFERENCE CALL MEETING |
| | IT WAS DISCUSSED AND THE WRITTEN COMMENT RESPONSE |
| | INDICATES WING WALLS ARE TO BE ADDED FOR COMPLIANCE |
| | WITH PROTRUSION LIMITS. NOT FOUND ON THE UPDATED PLAN |
| | A2.0 AS NOTED. SHEET A2.1 THE ENLARGED RESTROOM DETAIL |
| | # 1 SHOWS THE HIGH/ LOW DRINKING FOUNTAINS AND REV.# 7 |
| | BUT THERE IS NO ELEVATION VIEW TO INDICATE THE TYPE OF |
| | DRINKING FOUNTAIN AND COMPLIANCE WITH PROTRUDING |
| | OBJECTS AS FOUND ON SHEET A1.2. THE ISSUE, MAYBE WITH |
| | THE HIGH DRINKING FOUNTAIN IS A SKIRT MAYBE NEED TO BE |
| | ADDED TO THE BOTTOM OF THE ENCLOSURE FOR COMPLIANCE |
| | WITH PROTRUDING OBJECTS FROM THE WALL AND COMPLIANCE |
| | WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION 307.2 |
| | PROTRUSION LIMITS. OBJECTS WITH THE LEADING EDGE MORE |
| | THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE |
| | FINISH FLOOR OR GROUND SHALL PROTRUDE 4 INCHES MAXIMUM |
| | HORIZONTALLY INTO THE CIRCULATION PATH. |
| | |
| | 4) BUILDING PROVISO: SHEET S201 SHOWS WELDED |
| | CONNECTIONS TO THE BAR JOIST, STIFFENERS, ADDITIONAL |
| | STEEL FRAMING AROUND NEW ROOF TOP OPENINGS. WELDED OR |
| | BOLTED CONNECTIONS. THE CONTRACTOR IS REQUIRED TO |
| | PROVIDE WELD PROCEDURE SPECIFICATIONS & WELDER OPERATOR |
| | PERFORMANCE QUALIFICATION RECORDS IN ACCORDANCE WITH |
| | THE REFERENCED STANDARDS AT TIME OF INSPECTION. IN |
| | ACCORDANCE WITH THE AMERICAN WELDING SOCIETY. |
| | 11A) 2017 FBC-B 2204.1 WELDING |
| | 11B) 2017 FBC-B 2204.2 BOLTING. |
| | IF THERE IS ANY QUESTIONS ABOUT THE CODE REQUIREMENTS |
| | FOR THIS SECTION, PLEASE CONTACT THE CHIEF BUILDING |
| | INSPECTOR KEN CONRAD AT 561-805-6666. THANK YOU. |
| | |
| | 5A)BUILDING PROVISO/ DEFERRED SUBMITTALS CODE |
| | COMPLIANCE SHEET & A6.0: 13) COMPONENTS & CLADDING . |
| | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS ,MULLIONS |
| | (B) WINDOWS & MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 5B) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF |
| | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE |
| | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE |
| | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO |
| | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. |
| | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR |
| | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED |
| | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST |
| | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS |
| | FOR REVIEW BY THE BUILDING OFFICIAL. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 5C) IDENTIFY GLAZING/ MULLIONS. THE SUBMITTED PRODUCT |
| | APPROVALS THE ELEMENTS LISTED BELOW ARE NOT IDENTIFIED. |
| | PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE |
| | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION |
| | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH |
| | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, |
| | TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED |
| | OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND |
| | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B |
| | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE |
| | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER'S |
| | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE |
| | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED |
| | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. |
| | |
| | 5D) THE ROOF TOP A/C STAND PRODUCT APPROVALS, TO BE |
| | REVIEWED BY THE DESIGNER OF RECORD. PLEASE IDENTIFY THE |
| | FOLLOWING REQUIREMENTS CALCULATING THE AREA (SIDE VIEW) |
| | OF THE ROOF TOP COMPRESSORS, CONFIGURATION ON STAND, |
| | THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS, |
| | WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES, |
| | ANCHORS AND UPLIFT VERSES MOMENT FOR THE UNIT TO THE |
| | STAND AND THE STAND TO THE ROOF. THE PRODUCT APPROVAL |
| | IS TO BE REVIEWED BY THE DESIGNER OF RECORD, APPROVED |
| | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. |
| | |