2020-06-05 15:32:553RD REVIEW FBC-2017 PLUMBING
 PERMIT #20010941
 6/5/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A2.0: THE CORRECTED PLAN SHOWS THE NEW
 DRINKING FOUNTAIN ALCOVE WALL HAS REDUCED THE REQUIRED
 24" WHEEL CHAIR APPROACH TO THE MEN'S ROOM DOOR TO 11"-
 SEE FIGURE 404.2.4.1(K) FBC ACC.
  
 2) SHEETS A2.1 & A.2.1.1: PLEASE CORRECT THE 54" CLEAR
 FLOOR SPACE LENGTH MEASUREMENT FOR THE WATER CLOSETS TO
 59"- FIGURE 604.8.1.1 FBC ACC.
  
 3) SHEET P1.0 EXISTING GREASE INTERCEPTOR AND GREASE
 WASTE DISPOSAL SYSTEM:
 A) THE FLOOR SINKS AT THE BEVERAGE EQUIPMENT LINE SHALL
 BE CONNECTED TO THE GREASY WASTE LINE AND EXISTING
 GREASE INTERCEPTORS IF THE WASTE EFFLUENT FROM THE
 EQUIPMENT CONTAINS MILK FATS, OR OTHER WASTES LADEN
 WITH FATS, OILS, OR GREASE- SECTION 1003.3.1 FBC P.
 B) THE TYPE AND GALLON SIZE OF THE EXISTING GREASE
 INTERCEPTOR SHALL BE PLACED ON THE PLAN, ALONG WITH
 GREASE WASTE CALCULATIONS FOR THE NEW FIXTURES
 CONNECTING TO THE GREASE WASTE LINE. PLEASE SEE SECTION
 1003.3.1, 1003.3.4 FOR SIZING ACCORDING TO PDI-G-101
 STANDARD SIZING METHODS FOR HYDRO MECHANICAL
 INTERCEPTORS AND 1003.3.4 EXCEPTION FOR INTERCEPTORS
 THAT ARE SIZED, CONSTRUCTED AND APPROVED IN ACCORDANCE
 WITH RULE 64E-6, FLORIDA ADMINISTRATIVE CODE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719