| | PLUMBING COMMENTS: |
| | |
| | 1. PROVIDE PLUMBING PLAN SHOWING WATER ISOMETRIC . PER |
| | WPB AMEND TO FBC 107.3.5.1.3(13) |
| | |
| | 2. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE |
| | QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER |
| | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE |
| | MANUFACTURER?S INSTRUCTIONS. WATER-HAMMER ARRESTORS |
| | SHALL CONFORM TO ASSE 1010. PER FBC PL 604.9 |
| | |
| | 3. A BACKFLOW WILL BE REQUIRED FRO WATER COOLER SUPPLY |
| | LINE. PER FBC PL 608.3 |
| | |
| | 4. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS AND |
| | INSTILLATION GUIDE FOR WATER COOLER. PER WPB AMEND TO |
| | FBC 107.2.1 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |