Plan Review Notes
Plan Review Notes For Permit 19120988
Permit Number 19120988
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2020-03-17 10:11:52PLAN REVIEW - NFIP ELEVATION CERTIFICATE - BUILDING
 UNDER CONSTRUCTION
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER - BUILDING - PX3169
 PLANS EXAMINER - 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES.
 ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
  
 1) CORRECTED
 (DIAGRAM NUMBER CHANGED TO 1B)
  
 2) CORRECTED
  
 3) A9(C) ENTER NET AREA OF OPENINGS. PRODUCT APPROVAL
 FL58822-R3 SHOWS MODEL 1540-520 AT .53 SQ. FT. PER
 VENT. (NOT CORRECTED)
 (4 VENTS INSTALLED @ .53 SQ. FT PER VENT = 2.12 SQ. FT.
 X 144 SQ. INCHES/SQ.FT. = 305.28 SQ. INCHES)
 (CHANGE A9 (C) FROM 2.11 SQ. IN. TO 305.28 SQ. IN.)
  
 4) CORRECTED
 (ENGINEERED FLOOD OPENINGS SELECTED)
  
 5) PLEASE STATE IN COMMENTS WHAT VERTICAL DATUM WAS
 UTILIZED FOR A5. (NOT CORRECTED) (CORRECTION TO
 ORIGINAL REVIEW COMMENT REQUIRED)
 (PER FEMA ELEVATION CERTIFICATE INSTRUCTIONS, SECTION A
 - PROPERTY INFORMATION, ITEM A5 THE FOLLOWING
 INFORMATION IS REQUIRED -PART 1 - WHEN THE LATITUDE AND
 LONGITUDE ARE PROVIDED BY A SURVEYOR, CHECK THE "YES"
 BOX IN SECTION D AND INDICATE THE METHOD USED TO
 DETERMINE THE LATITUDE AND LONGITUDE IN THE COMMENTS
 AREA OF SECTION D. (EXAMPLES: LATITUDE AND LONGITUDE
 OBTAINED BY MAGELLEN GPS BLAZER 12 / LATITUDE AND
 LONGITUDE DETERMINED BY GOOGLEEARTH.COM / ETC.),
 PART 2 - SELECT HORIZONTAL DATUM USED - NAD 1983 WAS
 SELECTED )
  
 NEW COMMENT:
  
 UPON SUBMITTAL OF FINISHED CONSTRUCTION ELEVATION
 CERTIFICATE, PROVIDE THE FOLLOWING INFORMATION:
  
 6) C2 (E) LOWEST ELEVATION OF MACHINERY OR EQUIPMENT
 SERVICING THE BUILDING SHALL BE AT OR ABOVE DFE OF 9.0
 FEET NAVD
  
 7) FEMA ELEVATION CERTIFICATES ARE LEGAL DOCUMENTS,
 BUILDING OWNER'S NAME IN SECTION A1 MUST BE PERMAMENT
 AND CANNOT BE ALTERED.
  
 8) PHOTOGRAPHS PROVIDED WITH ELEVATION CERTIFICATE
 INDICATE 1ST FLOOR HAS NOT BEEN CAST. AN UNDER
 CONSTRUCTION ELEVATION CERTIFICATE REQUIRES THE FIRST
 FLOOR TO BE IN PLACE - SEE SECTION C2 (A), PG. 2 OF 6
 OF ELEVATION CERTIFICATE AND FEMA ELVATION CERTIFICATE
 INSTRUCTIONS ITEMS C2. A-D, PG. 4 OF 9.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  