| 2020-03-17 10:11:52 | PLAN REVIEW - NFIP ELEVATION CERTIFICATE - BUILDING |
| | UNDER CONSTRUCTION |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER - BUILDING - PX3169 |
| | PLANS EXAMINER - 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 3RD REVIEW |
| | |
| | RESULTS: DENIED |
| | |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS |
| | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY |
| | HAVE ADDITIONAL COMMENTS IN PARENTHESES. |
| | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. |
| | |
| | |
| | 1) CORRECTED |
| | (DIAGRAM NUMBER CHANGED TO 1B) |
| | |
| | 2) CORRECTED |
| | |
| | 3) A9(C) ENTER NET AREA OF OPENINGS. PRODUCT APPROVAL |
| | FL58822-R3 SHOWS MODEL 1540-520 AT .53 SQ. FT. PER |
| | VENT. (NOT CORRECTED) |
| | (4 VENTS INSTALLED @ .53 SQ. FT PER VENT = 2.12 SQ. FT. |
| | X 144 SQ. INCHES/SQ.FT. = 305.28 SQ. INCHES) |
| | (CHANGE A9 (C) FROM 2.11 SQ. IN. TO 305.28 SQ. IN.) |
| | |
| | 4) CORRECTED |
| | (ENGINEERED FLOOD OPENINGS SELECTED) |
| | |
| | 5) PLEASE STATE IN COMMENTS WHAT VERTICAL DATUM WAS |
| | UTILIZED FOR A5. (NOT CORRECTED) (CORRECTION TO |
| | ORIGINAL REVIEW COMMENT REQUIRED) |
| | (PER FEMA ELEVATION CERTIFICATE INSTRUCTIONS, SECTION A |
| | - PROPERTY INFORMATION, ITEM A5 THE FOLLOWING |
| | INFORMATION IS REQUIRED -PART 1 - WHEN THE LATITUDE AND |
| | LONGITUDE ARE PROVIDED BY A SURVEYOR, CHECK THE "YES" |
| | BOX IN SECTION D AND INDICATE THE METHOD USED TO |
| | DETERMINE THE LATITUDE AND LONGITUDE IN THE COMMENTS |
| | AREA OF SECTION D. (EXAMPLES: LATITUDE AND LONGITUDE |
| | OBTAINED BY MAGELLEN GPS BLAZER 12 / LATITUDE AND |
| | LONGITUDE DETERMINED BY GOOGLEEARTH.COM / ETC.), |
| | PART 2 - SELECT HORIZONTAL DATUM USED - NAD 1983 WAS |
| | SELECTED ) |
| | |
| | NEW COMMENT: |
| | |
| | UPON SUBMITTAL OF FINISHED CONSTRUCTION ELEVATION |
| | CERTIFICATE, PROVIDE THE FOLLOWING INFORMATION: |
| | |
| | 6) C2 (E) LOWEST ELEVATION OF MACHINERY OR EQUIPMENT |
| | SERVICING THE BUILDING SHALL BE AT OR ABOVE DFE OF 9.0 |
| | FEET NAVD |
| | |
| | 7) FEMA ELEVATION CERTIFICATES ARE LEGAL DOCUMENTS, |
| | BUILDING OWNER'S NAME IN SECTION A1 MUST BE PERMAMENT |
| | AND CANNOT BE ALTERED. |
| | |
| | 8) PHOTOGRAPHS PROVIDED WITH ELEVATION CERTIFICATE |
| | INDICATE 1ST FLOOR HAS NOT BEEN CAST. AN UNDER |
| | CONSTRUCTION ELEVATION CERTIFICATE REQUIRES THE FIRST |
| | FLOOR TO BE IN PLACE - SEE SECTION C2 (A), PG. 2 OF 6 |
| | OF ELEVATION CERTIFICATE AND FEMA ELVATION CERTIFICATE |
| | INSTRUCTIONS ITEMS C2. A-D, PG. 4 OF 9. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |