| 2020-05-05 12:20:17 | |
| | 3RD REVIEW FBC-2017 PLUMBING |
| | PERMIT #19120885 |
| | 5/5/2020 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) A PRODUCT DATA SHEET HAS BEEN SUBMITTED FOR A NEW |
| | 28-GALLON ELECTRIC WATER HEATER HOWEVER THE PLANS SHOW |
| | ALL EXISTING WATER HEATERS. PLEASE SHOW THE LOCATION OF |
| | THE NEW WATER HEATER AND ADD IT TO THE THE PLUMBING |
| | SCOPE OF WORK ON SHEET 1- SECTION 107.2.1 WPB. PLEASE |
| | NOTE THAT A THERMAL EXPANSION DEVICE IS REQUIRED TO BE |
| | INSTALLED AT THE SUPPLY LINE TO THE WATER HEATER PER |
| | SECTION P2903.4 FBC RES. |
| | |
| | 2) TWO DWELLING UNITS ARE SHOWN TO BE OR THE SAME LOT |
| | WHICH REQJUIRES INSTALLATION OF AN RPZ-TYPE BACKFLOW |
| | PREVENTER TO BE INSTALLED AT THE WATER METER ACCORDING |
| | TO THE CITY OF WPB CROSS-CONNECTION MANUAL. A SEPARATE |
| | PERMIT IS REQUIRED FOR THE INSTALLATION. PLEASE CONTACT |
| | THE THE CITY OF WPB UTILITIES DEPT. AT 561-822-2240 FOR |
| | MORE INFORMATION. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |
| 2020-04-30 15:33:07 | 04/30/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) |
| | |
| | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE |
| | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN |
| | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM |
| | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND |
| | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF |
| | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY |
| | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM |
| | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES |
| | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO |
| | AVOID VOIDING OF THE PERMIT. |
| | |
| | LUIS A. CRESPO |
| | PLUMBING INSPECTOR / |
| | PLUMBING PLAN REVIEW |
| | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM |
| | [email protected] |
| | 561-701-6437 |
| | |