| 2020-01-22 14:53:58 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19120806 |
| | ADD: 460 S ROSEMARY AVE. SUITE: 186 |
| | CONT: SOUTH FLORIDA CONSTRUCTION GROUP |
| | TEL: 954-782-1260 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. JAN. 22/2020 |
| | ACTION: DENIED |
| | |
| | 1) SHEET S0.00 GENERAL NOTES UNDER THE HEADING OF WIND |
| | DESIGN THE PROVIDED PRESSURES ARE IN VULT. PLEASE |
| | CONVERT THEM TO VASD SINCE THE PRODUCT APPROVALS ARE |
| | ALL IN VASD. IT DOES APPEAR THE PRESSURES ARE GOOD FOR |
| | WALL ZONES 4 & 5 AND ROOF ZONES 1, 2 & 3. THANK YOU. |
| | 2017 FBC-B 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| | |
| | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |