 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 AT TIME OF INSPECTION, THE VERTICAL CHANGE IN LEVEL
 (MAX. 1/4") AT THE NEW DOOR OPENING SHALL COMPLY WITH
 SECTION FBC A 303.
  
 THE DOORS 105A AND 105B WILL NEED TO HAVE 48"
 SEPARATION IF THIS BATHROOM IS NOT DESIGNATED FOR ONLY
 ONE PERSON AT A TIME (PRIVATE). AT TIME OF INSPECTION,
 PER FBC A 404.2.6, REMOVAL OF THE BATHROOM DOOR # 105B
 MAY BE REQUIRED.
  
 FOR ANY WELDING ON THIS PROJECT:
 AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  
  