| Plan Review Notes For Permit 19120803 |
| Permit Number |
19120803 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2020-05-05 08:49:53 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW APPROVED WITH PROVISOS: | | | | | | AT TIME OF INSPECTION, THE VERTICAL CHANGE IN LEVEL | | | (MAX. 1/4") AT THE NEW DOOR OPENING SHALL COMPLY WITH | | | SECTION FBC A 303. | | | | | | THE DOORS 105A AND 105B WILL NEED TO HAVE 48" | | | SEPARATION IF THIS BATHROOM IS NOT DESIGNATED FOR ONLY | | | ONE PERSON AT A TIME (PRIVATE). AT TIME OF INSPECTION, | | | PER FBC A 404.2.6, REMOVAL OF THE BATHROOM DOOR # 105B | | | MAY BE REQUIRED. | | | | | | FOR ANY WELDING ON THIS PROJECT: | | | AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | | BE USED. | | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | | | | |
|