| Date |
Text |
| 2020-03-09 18:27:52 | RESIDENTIAL (R2) SECOND BUILDING REVIEW CHECKLIST. |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | |
| | |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | ORIGINAL COMMENT: |
| | 1- PLANS CALL FOR INSTALLATION OF TILE IN KITCHENS AND |
| | BATHROOMS. NEED TO PROVIDE SOUND INSULATION ON SECOND |
| | FLOOR UNITS WHERE WORK IS PERFORMED. SEC. 702.6 |
| | FBC-EXISTING BUILDING AND SEC. 1207 FBC-BUILDING. |
| | PLEASE PROVIDE THE FOLLOWING: |
| | |
| | A) OK |
| | |
| | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS |
| | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS |
| | REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT PROVIDED. |
| | |
| | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS |
| | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS |
| | REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT PROVIDED. |
| | |
| | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING |
| | CONSTRUCTION AND PROPOSED FLOOR FINISH. |
| | |
| | |
| | ORIGINAL COMMENT: |
| | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR THE PAIR OF EXTERIOR DOOR TO BE |
| | REPLACED AS SPECIFIED ON OUTSIDE OF UNIT #4 ON FIRST |
| | FLOOR PLAN ON SHEET A-1. |
| | |
| | RESPONSE: |
| | DOOR PRODUCT APPROVAL SUBMITTED IS INCOMPLETE. NEED TO |
| | PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL (2 COPIES), |
| | INCLUDING THE FLORIDA PRODUCT APPROVAL COVER PAGE THAT |
| | CORRESPONDS TO THE DRAWINGS SUBMITTED. THE FLORIDA |
| | PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS IF |
| | PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT. |
| | |
| | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |