| 2020-01-16 18:49:45 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SHEET 4 OF 5 OF PRODUCT APPROVAL FL11291-R7 REQUIRES | | | A 3-1/2" EDGE DISTANCE FOR THE ANCHOR SPACING OF 12" | | | LISTED IN THE TABLE. A 3" EDGE DISTANCE IS SPECIFIED IN | | | THE INSTALLATION SCHEDULE THAT WAS SUBMITTED. THE NOTES | | | THAT ARE BELOW THE TABLE REQUIRES THE ANCHOR SPACING IN | | | THE TABLE TO BE MULTIPLIED BY .86 WHEN THE EDGE | | | DISTANCE IS 3". THEREFORE THE SPACING WOULD BE 10.32 " | | | WHICH IS 12" X .86. PLEASE CORRECT. | | | | | | 2) IT IS NOT CLEAR WHICH METHOD OF ATTACHMENT WILL BE | | | USED TO INSTALL THE STORM CATCHER ABATEMENT SCREEN | | | SYSTEM. THERE ARE SEVERAL DIFFERENT WAYS TO ATTACH THE | | | FABRIC TO THE STRUCTURE SHOWN IN THE PRODUCT APPROVAL. | | | CIRCLE THE APPROPRIATE ITEMS IN THE PRODUCT APPROVAL | | | AND PROVIDE A DIAGRAM DRAWING THAT CLEARLY SHOWS HOW | | | THE FABRIC WILL BE INSTALLED. FBC 107.2.1 | | | |
|