| Date |
Text |
| 2020-07-27 10:28:21 | 07/27/20 2ND PLUMBING REVIEW **DENIED** WITH COMMENTS |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | 1. SCOPE OF WORK IS NOT CLEAR OF WHAT IS BEING DONE ON |
| | YOU PLUMBING PAGE. PLEASE GIVE A DESCRIPTIVE NARRATIVE |
| | OF WHAT IS IN AND WHAT IS BEING REPLACED PER THE FBC |
| | WPB A 101.2. |
| | 2. A SUB PLUMBING PERMIT IS REQUIRED FOR THE SCOPE OF |
| | WORK PER THE WPB AMENDMENTS TO THE FBC SEC. 105.1. |
| | 3. PLUMBING RISER DIAGRAM REQUIRED, PLEASE SHOW VENTS |
| | THROUGH ROOF, CLEAN OUT OUTSIDE BUILDING AND PIPE SIZES |
| | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) |
| | RESIDENTIAL PLUMBING. |
| | 4. A STOVE IS SHOWN ON PLANS IS IT GAS, PLEASE LABEL IF |
| | IT IS, A PERMIT ALONG WITH AN EVALUATION IS REQUIRED IS |
| | USING GAS AS THE CITY DOES NOT SHOW A PERMIT ON FILE |
| | FOR GAS PER THE 2017 FBC WPB A 107.1. |
| | 5. CLEAN-OUT OUTSIDE OF BUILDING SHALL BE WITHIN 10' |
| | FOR EACH ENTRANCE IN ITS OWN SYSTEM PLEASE SHOW |
| | DISTANCE AND CLEAN OUTS AS ONE IS MISSING ON GUEST BATH |
| | PER THE 2017 FBC R3005.2.3. |
| | 6. PLANS ARE REQUIRED TO BE DESIGNED AND SIGNED AND |
| | SEALED BY A LICENSED ENGINEER OR ARCHITECT. PLANS |
| | FURNISHED BY AN INTERIOR DESIGNER ARE NOT ACCEPTABLE. |
| | PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; FBC |
| | 107.2.1, 107.3.5 |
| | |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | LUIS A. CRESPO |
| | PLUMBING INSPECTOR / |
| | PLUMBING PLAN REVIEW |
| | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM |
| | [email protected] |
| | 561-701-6437 |
| | |
| | |