| 2019-12-14 08:15:53 | PLAN REVIEW - BUILDING |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | 1&2 FAMILY PLANS EXAMINER, SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. SIX FOOT HIGH WALL LOCATED AT NW ELEVATION |
| | ENCROACHES INTO 2.5 FOOT FPU EASEMENT. UTILITY RELEASE |
| | FROM FPU REQUIRED PRIOR TO BLDG. APPROVAL. NEW PLAN |
| | PAGE AND SIGNATURE REVIEW MAY BE REQUIRED. |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | NOTICE: STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD |
| | AREA AE WITH BASE FLOOD ELEVATIONS OF 6 & 7 FEET NAVD. |
| | |
| | R322.1.2STRUCTURAL SYSTEMS. |
| | STRUCTURAL SYSTEMS OF BUILDINGS AND STRUCTURES SHALL BE |
| | DESIGNED, CONNECTED AND ANCHORED TO RESIST FLOTATION, |
| | COLLAPSE OR PERMANENT LATERAL MOVEMENT DUE TO |
| | STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TO |
| | THE DESIGN FLOOD ELEVATION. |
| | |
| | R322.2.3FOUNDATION DESIGN AND CONSTRUCTION. |
| | FOUNDATION WALLS FOR BUILDINGS AND STRUCTURES ERECTED |
| | IN FLOOD HAZARD AREAS SHALL MEET THE REQUIREMENTS OF |
| | CHAPTER 4. |
| | |
| | |