Plan Review Notes
Plan Review Notes For Permit 19111287
Permit Number 19111287
Review Stop P
Sequence Number 1
Notes
Date Text
2019-12-24 13:52:251ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW 60" CLEAR FLOOR SPACE IN ALL THE CAFE.
 PER FBC ACC 804.2.2
  
 2. ON ALL REMODELS 20% OF THE TOTAL COST OF THE JOB
 SHALL BE SPENT ON BRING UP THE LEVEL OF ACCESSIBILITY
 PLEASE PROVIDE A COST BREAKDOWN TO SHOW COMPLIANCE WITH
 FBC ACC 202.4.1, 202.4.2
  
 3. PROVIDE THE EXISTING LAYOUT OF THE BATHROOMS. PER
 WPB AMEND TO FBC 107.2.1
  
 4. SHOW COMPLIANCE WITH FBC ACC 602.4 , 602.7,602.2 THE
 CLEAR FLOOR SPACE SHALL BE FOR A FRONT APPROACH. WITH 2
 SPOUTS.
  
 END OF COMMENTS
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]