| 2020-06-24 15:05:02 | PLAN REVIEW - BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | 3RD REVIEW |
| | |
| | RESULTS: DENIED |
| | |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. |
| | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| | SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. |
| | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. |
| | |
| | 2ND REVIEW |
| | |
| | |
| | ****IMPORTANT: |
| | ENERGY CALCULATIONS NEED TO BE SIGNED BY THE OWNER |
| | PRIOR TO ISSUING THE PERMIT. |
| | |
| | 1- CORRECTED |
| | |
| | 2- CORRECTED |
| | |
| | 3- CORRECTED |
| | |
| | 4- IMPACT FEE. (SEE IMPACT FEE REVIEW) |
| | |
| | |
| | 5- DESIGNER SHALL SELECT MODEL OF EXTERIOR DOORS TO BE |
| | INSTALLED. (NOT ADDRESSED) |
| | |
| | DESIGNER SHALL REVIEW AND APPROVE PRODUCT APPROVALS. |
| | (NOT ADDRESSED) |
| | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. |
| | |
| | A) METAL ROOFING. (NOT ADDRESSED) |
| | |
| | B) ROOFING TILES.(NOT ADDRESSED) |
| | |
| | C) GARAGE OVERHEAD DOOR DOOR. NEED TO PROVIDE PRODUCT |
| | APPROVAL FOR DOOR THAT MEETS THE DESIGN PRESSURE |
| | CALCULATED BY THE ARCHITECT OF RECORD ON SHEET A-2.0. |
| | (NOT ADDRESSED) |
| | |
| | D) NEED PRODUCT APPROVAL FOR ARCHED ENTRY DOOR AS SHOWN |
| | ON PLANS. (NOT ADDRESSED) |
| | |
| | E) NEED PRODUCT APPROVAL FOR FLAT ROOF AT THE PORTE |
| | COCHERE. (NOT ADDRESSED) |
| | |
| | NEW COMMENTS: |
| | |
| | 6- SPECIFIED FOOTING SIZE WF5 -20 DOESN'T COMPLY WITH |
| | THE MINIMUM FOOTING DEPTH REQUIRED BY SEC. R403.1.4 |
| | FBC-RESIDENTIAL. REVISE FOOTING SIZE AS REQUIRED. NOTE: |
| | REVISE TYPICAL WALL SECTION ON SHEET A-3.0 ALSO. KEEP |
| | IN MIND THAT NEED TO PROVIDE THE 6" CLEARANCE FOR |
| | TERMITE INSPECTION. (NOT ADDRESSED) |
| | |
| | 7- TYPE OF DOOR SHOWN ON THE DOOR TYPES ON SHEET A-1.0 |
| | DOESN'T MATCH TYPE OF DOOR SHOWN ON THE EXTERIOR |
| | ELEVATION. EXTERIOR ELEVATION SHOWS AN ARCHED DOOR. |
| | REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY |
| | AMENDMENTS. PRODUCT APPROVAL REQUIRED FOR ARCHED DOOR. |
| | (NOT ADDRESSED) |
| | |
| | 8- ENERGY CALCULATIONS SUBMITTED: (NOT ADDRESSED) |
| | |
| | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED |
| | AND DATED BY THE OWNER, ARCHITECT OR OWNER?S LEGALLY |
| | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS |
| | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, |
| | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO |
| | BEGIN CONSTRUCTION. |
| | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING COMPLETE ADDRESS, OWNER'S INFORMATION, THE |
| | BUILDER'S NAME, PERMIT OFFICE AND JURISDICTION |
| | (604700). SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| | C) THE AREA WEIGHTED AVERAGE SHGC SHOWN ON ITEM #7 ON |
| | PAGE 1 DOESN'T COMPLY WITH THE MAXIMUM FENESTRATION |
| | SHGC REQUIRED BY SEC. R405.5.3.4 OF FBC-ENERGY |
| | CONSERVATION. THE MAXIMUM AREA WEIGHTED AVERAGE |
| | FENESTRATION SHGC ALLOWED IS 0.50. ENERGY CALCULATIONS |
| | SUBMITTED SHOW 0.754. REVISE AS REQUIRED TO COMPLY. |
| | |
| | D) FLOOR TYPE SHOWN ON ITEM #8 ON PAGE 1 IS INCORRECT |
| | AND IT DOESN'T MATCH FLOOR PLANS. REVISE AS REQUIRED TO |
| | MATCH. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. (NOT |
| | ADDRESSED) |
| | |
| | E)REVISE ITEM #9(A) TO MATCH PLANS. INSULATION R-VALUE |
| | DOESN'T MATCH PLANS. SEE PLANS AND REVISE AS REQUIRED. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. (NOT |
| | ADDRESSED) |
| | |
| | F) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 5. |
| | TYPICALLY, THE RATIO IS 1/150 NOT 1/300. SEC. R806.2 |
| | FBC-RESIDENTIAL. OR PERSON PREPARING THE ENERGY |
| | CALCULATIONS TO PROVIDE COMPLETE DETAILS/SPECIFICATIONS |
| | SHOWING COMPLIANCE WITH THE 1/300 RATIO AS REQUIRED BY |
| | THE EXCEPTION ON SEC. R806.2. NOTE: ARCHITECT OF RECORD |
| | NEEDS TO REVIEW/APPROVE THEM PRIOR TO SUBMITTAL. (NOT |
| | ADDRESSED) |
| | |
| | G) REVISE WINDOWS OVERHANG SEPARATION TO MATCH PLANS. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. (NOT |
| | ADDRESSED) |
| | |
| | 9- ARCHITECTURAL PLANS SHOW CEILING FANS AND THE ENERGY |
| | CALCULATIONS ARE TAKING THE CREDIT FOR THEM. NEED TO |
| | SPECIFY THE CEILING FAN SIZE ON EACH ROOM SHOWING |
| | COMPLIANCE WITH TABLE R405.7.6 FBC-ENERGY CONSERVATION. |
| | (NOT ADDRESSED) |
| | |
| | 10- CORRECTED |
| | |
| | 11- PROPOSED FLOOR PLAN ON SHEET A-1.0 SHOWS 3'-0" |
| | MASONRY OPENING FOR THE ENTRY DOOR. THIS MASONRY |
| | OPENING DIMENSION IS INCORRECT FOR THE REQUIRED 3'-0" |
| | DOOR. REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| | (NOT CORRECTED) |
| | |
| | 12- PROVIDE STRUCTURAL BUCK DETAIL AND SPECIFICATIONS |
| | FOR NEW OVERHEAD GARAGE DOOR. SEC. R301.1 |
| | FBC-RESIDENTIAL. (NOT CORRECTED) |
| | |
| | 13- NEW PORTE COCHERE: (NOT ADDRESSED) |
| | A) ROOF FRAMING PLAN ON SHEET S-2.0: PROVIDE COMPLETE |
| | DETAILS AND SPECIFICATIONS FOR THE FASTENING OF THE |
| | 2X10 ROOF JOISTS. PROVIDE COMPLETE DETAILS/SPECS FOR |
| | THE WOOD LEDGER, FASTENERS, ETC. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | NOTE: THERE IS NOT METAL ROOFING ON A FLAT ROOF. REVISE |
| | ROOF SPECS. |
| | |
| | B) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING |
| | COMPLIANCE WITH THE ROOF DRAINAGE INCLUDING EMERGENCY |
| | SCUPPERS. SEC. R903.4 FBC-RESIDENTIAL. (NOT ADDRESSED) |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | |
| | |
| | |