| Date |
Text |
| 2019-12-19 14:56:34 | 1ST REVIEW FBC-2017 MECHANICAL |
| | PERMIT #19110703 |
| | 12/19/19 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED FOR REVIEW- |
| | SECTION 107.2.1 WPB. |
| | |
| | 2) PLEASE IDENTIFY THE LARGE ROOM ON THE SUBMITTED |
| | OWNER/BUILDER PLAN- SECTION 107.2.1 WPB. |
| | |
| | 3) INDICATE HOW THE LARGE ROOM WILL BE VENTILATED- |
| | NATURALLY OR MECHANICALLY. IF USING NATURAL SHOW |
| | COMPLIANCE WITH SECTION R303.1 FBC RES AND VERIFY THE |
| | OPENABLE AREA (WINDOWS, DOORS) TO THE OUTDOORS IS NOT |
| | LESS THAN 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. |
| | |
| | 4) REFER TO SECTION R303.10 FBC RES AND INDICATE HOW |
| | HEATING WILL BE PROVIDED TO THE NEW ADDITION. PLEASE |
| | NOTE THAT PORTABLE SPACE HEATERS SHALL NOT BE USED TO |
| | ACHIEVE COMPLIANCE. |
| | |
| | 5) REFER TO SECTION R303.3 AND INDICATE HOW THE |
| | BATHROOM WILL BE VENTILATED- NATURALLY THROUGH AN |
| | OPERABLE WINDOW OR MECHANICALLY PER SECTION M1507 FBC |
| | RES. |
| | |
| | 6) THE CONVERSION OF THE GARAGE INTO HABITAL, |
| | CONDITIONED SPACE IS CLASSIFED AS BOTH AN ADDITION AND |
| | A CHANGE OF OCCUPANCY PER SECTIONS R202, R503.2, AND |
| | R505.2 FBC EC. PLEASE PROVIDE AN ENERGY COMPLAINCE |
| | REPORT IN ACCORDANCE WITH SECTION R101.5.1.1 FBC EC. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| | KEEP THEM WITH THE SUBMITTALS. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |