| 2020-03-31 13:37:35 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19110539 (FA?ADE RENOVATIONS & NEW |
| | COMPONENTS AND CLADDING) |
| | ADD: 600 NORTHPOINT PARKWAY |
| | CONT:TBD/ TO BE DETERMINED |
| | TEL: ?????? CONTACT: ASHLEE CALLAHAN |
| | E-MAIL:[email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | PERMITS ASSOCIATED WITH THE OVERALL PROJECT. |
| | 19110539 FA?ADE RENOVATIONS & NEW CLADDING |
| | ???????? PORTE COCHERE |
| | 19120240 INT. REMODEL OF GUEST ROOMS |
| | 19120241 INT. REMODEL OF CORRIDORS & PUBLIC SPACES. |
| | |
| | 1ST REVIEW |
| | DATE: 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1) SEMI-COMPLIED, VALUE FOR THIS PROJECT WAS INCREASED |
| | TO $825,000.00 DOLLARS IN VALUE IN THE NEW PERMIT |
| | APPLICATION. THE RESPONSE LETTER FROM THE DESIGN |
| | PROFESSIONAL STATES THE CORRECT VALUE OF THE PROJECT IS |
| | $750,000.00 DOLLARS IN VALUE. PLEASE NOTE THERE SEEMS |
| | TO BE A DISCREPANCY OF OPINION. |
| | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 107.2.1.2 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 2) 2ND REVIEW/ SEMI-COMPLIED. THE QUESTION WAS ASKED |
| | SHEET G100 STATES THE NEW PORTE CACHERE IS TO BE |
| | PROVIDED BY THE OWNER AND INSTALLED BY OTHERS (ANOTHER |
| | CONTRACTOR). THE RESPONSE WAS NOT PART OF THIS PERMIT, |
| | IT IS TO BE SUBMITTED UNDER SEPARATE PERMIT, REVIEW AND |
| | ASSOCIATED FEES. THERE SEEMS TO BE A DISCONNECT ON THE |
| | SUBMITTAL SIDE AND THE DESIGNER OF RECORD. IN THE |
| | RESPONSE TO COMMENTS 2, 3 & 4 THE DESIGNER OF RECORD |
| | REPEATEDLY STATED THAT THE PORTE COCHERE WOULD BE UNDER |
| | SEPARATE PERMIT. UNDER THE 2ND REVIEW A NEW PERMIT |
| | APPLICATION WAS ADDED UNDER THE DESCRIPTION OF WORK |
| | ADDITIONAL WORDING WAS ADDED ( + PORTE COCHERE). THE |
| | VALUE OF THE PERMIT WAS INCREASE TO THE DOLLAR AMOUNT |
| | OF $825,000.00 IN VALUE. DISCREPANCY IN WHAT IS TO BE |
| | COVERED UNDER THE SCOPE OF THIS PERMIT. FOR THIS REVIEW |
| | I?M GOING TO TAKE THE ARCHITECT AS THE DESIGNER OF |
| | RECORD AS MAKING ALL THE CALLS ON THIS PROJECT, AND ALL |
| | INFORMATION SHOULD BE REVIEWED BY THE DESIGNER OF |
| | RECORD FOR ACCURACY AS IT PERTAINS TO THE PROJECT. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 3) SEMI-COMPLIED. THE DESIGNER OF RECORD HAS STATED |
| | THAT THE PORTE COCHERE WILL BE UNDER SEPARATE PERMIT, |
| | REVIEWS AND ASSOCIATED FEES. TO DATE NO PERMIT HAS BEEN |
| | APPLIED FOR, DISCREPANCY SEE COMMENT # 2. |
| | |
| | 4) SEMI-COMPLIED. THE DESIGNER OF RECORD HAS STATED |
| | THAT THE PORTE COCHERE WILL BE UNDER SEPARATE PERMIT, |
| | REVIEWS AND ASSOCIATED FEES. TO DATE NO PERMIT HAS BEEN |
| | APPLIED FOR, DISCREPANCY SEE COMMENT # 2. |
| | |
| | 5) 2ND REVIEW. NOT ADDRESSED. THE RESPONSE QUOTES |
| | REGULATIONS UNDER THE ZONING DIVISION, NOT REQUIREMENTS |
| | BY THE 2017 FBC-B. THE PORTE COCHERE TO BE CONSIDERED |
| | PART OF THE 3 STORY BUILDING IT WILL REQUIRE FIRE |
| | SPRINKLERS FOR A TYPE 5A BUILDING, OTHERWISE YOU ARE |
| | LOOKING AT 2 SEPARATE BUILDINGS ON THE SAME LOT. SEE |
| | 503.1.2 BUILDINGS ON THE SAME LOT WITH ASSUMED PROPERTY |
| | LINE. ALSO REVIEW BUILDING HEIGHT AND AREA LIMITATIONS |
| | SECTIONS 504 AND 506 FOR BUILDINGS TO COMPLY WITH THE |
| | PROVISIONS OF THIS CODE APPLICABLE TO THE AGGREGATE |
| | BUILDING FOR AREA AND HEIGHT. |
| | |
| | 6) 2ND REQUEST. SHEET G100 STATES THAT 5 OF THE 5 |
| | ACCESSIBLE PARKING SPACES ARE TO BE REGRADED AND |
| | RESTRIPED. THE REVISION STATES NOTE 3 THAT ALL WORK |
| | WILL BE IN THE ACCORDANCE WITH THE 2017 |
| | FBC-ACCESSIBILITY CODE. |
| | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. W.P.B. |
| | ADMINISTRATIVE CODE/2017 DRAWINGS & SPECIFICATIONS |
| | SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR |
| | OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE |
| | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| | CODES. SUCH INFORMATION SHALL BE SPECIFIC TO THE |
| | TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR IN |
| | PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS |
| | A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION |
| | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND |
| | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | PLEASE NOTE THE STATE ALLOWS THE JURISDICTION TO DECIDE |
| | SINGLE STRIPE OR DOUBLE STRIPE AND THE DIMENSIONS |
| | BETWEEN THE STRIPES. 2017 FBC-ACCESSIBILITY CODE |
| | ADVISORY 502.3.3 MARKINGS. THE METHOD AND COLOR OF |
| | MARKINGS ARE NOT SPECIFIED BY THIS REQUIREMENT BUT MAY |
| | BE ADDRESSED BY STATE OR LOCAL LAWS AND REGULATIONS. |
| | THE CITY OF WES PALM BEACH MUNI CODE ARTICLE XV 94-485 |
| | PARKING PROVIDE A DOUBLE LINED DIMENSIONED PARKING |
| | STALL DETAIL. |
| | |
| | 7) 2ND REQUEST. DEALS WITH SHEET G100ANDNOTE NUMBER 9TO |
| | PROVIDE NEW CURB WITH FLUSH TRANSITION AND 5 FOOT WIDE |
| | SIDEWALK TO THE NEW ACCESSIBLE PARKING SPACE. WITH |
| | REGARDS TO THE OTHER EXISTING ACCESSIBLE PARKING SPACES |
| | AND ACCESS AISLES TO THE EXISTING SIDEWALKS? ARE THE |
| | OTHER EXISTING ACCESSIBLE PARKING SPACES AND ACCESS |
| | AISLES WITH DROPPED CURBS WITH CURB RAMPS IN COMPLIANCE |
| | WITH THE 2017 FBC-ACCESSIBILITY CODE406 CURB RAMPS? THE |
| | RESPONSE INDICATES THAT COMPLIANCE WITH THE 2017 |
| | FBC-ACCESSIBILITY CODE WILL BE IN ACCORDANCE WITH THE |
| | 2017 FBC-ACCESSIBILITY CODE. |
| | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. W.P.B. |
| | ADMINISTRATIVE CODE/2017 DRAWINGS & SPECIFICATIONS |
| | SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR |
| | OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE |
| | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| | CODES. SUCH INFORMATION SHALL BE SPECIFIC TO THE |
| | TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR IN |
| | PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS |
| | A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION |
| | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND |
| | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 8) 2ND REQUEST. SHEET G100 INDICATES THE RE-USE OF THE |
| | EXISTING POOL GATE. I ASKED TO SHOW COMPLIANCE WITH |
| | SECTION 454.1.3.1.9 OF THE 2017 FBC-B REQUIREMENTS FOR |
| | THE GATE AND LATCHING REQUIRMENTS. SUBMITTED WAS |
| | EXHIBIT G. STANDARDS THE GATE AND LATCH HAS TO MEET. |
| | THERE WERE NO DOCUMENTS FOR THE GATE. 2017 WEST PALM |
| | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| | 1, ADMINISTRATION 107.2.1. W.P.B. ADMINISTRATIVE |
| | CODE/2017 DRAWINGS & SPECIFICATIONS SHALL CONTAIN |
| | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO |
| | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION |
| | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE |
| | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR |
| | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 9 &10) COMPLIED. |
| | |
| | 11) 2ND REVIEW. COMPONENTS AND CLADDING WERE SUBMITTED |
| | AS EXHIBITS A-E. PLEASE NOTE SINCE THE SUBMITTED |
| | PRODUCT APPROVALS ARE GOING THROUGH REVIEW ANY PRODUCT |
| | APPROVAL BEING SUBMITTED EACH PRODUCT APPROVAL WOULD |
| | THEN BE CONSIDERED SINCE THE CITY HAS PUT IN PLAN |
| | REVIEW TIME ON THE DOCUMENTS SUBMITTED AT TIME OF |
| | APPLICATION. |
| | |
| | |
| | 11) EXHIBIT A: TPO SINGLE PLY ROOF SYSTEM, ROOF NOA |
| | 15-0729.18 PAGES 16 & 17. FASTENER # 2. |
| | LIMITATION # 7. REVIEW THE PRODUCT APPROVAL |
| | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF |
| | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR |
| | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN |
| | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. |
| | CALCULATION PREPARED, SIGNED AND |
| | SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR |
| | REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. |
| | |
| | 11) EXHIBIT B: DRYVIT SYSTEMS OVER PLYWOOD, NOA |
| | 17-0807.19 +/- 100 PSF. GOOD. |
| | |
| | 11) EXHIBIT C: STOREFRONT. W.W. SCHAEFER ENG. KANEER |
| | ENG. EVALUATION 1-D, QUALITY ASSURANCE: ARCHITECTURAL |
| | TESTING INC. GOOD. |
| | |
| | 11) EXHIBIT D: ROOF TILE NOA 16-0314.06 TABLE 4 |
| | ATTACHMENT METHOD AND UPLIFT NOT IDENTIFIED/ CIRCLED. |
| | |
| | 11E) NICHIHA USA FIBER CEMENT WALL PANELS NOA: |
| | 16-0404.18 PRESSURES +45/ -55. GOOD. |
| | |
| | 12A) 2ND REQUEST. RESPONSE INDICATES CODE COMPLIANCE TO |
| | BE FOUND ON SHEET S002 UNDER SECTION E, FASTENERS. |
| | COMPLIANCE FOR WELDED AND BOLTED CONNECTIONS WAS NOT |
| | FOUND. |
| | |
| | WELDED OR BOLTED CONNECTIONS |
| | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE |
| | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE |
| | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED |
| | STANDARDS AT TIME OF INSPECTION. IN ACCORDANCE WITH THE |
| | AMERICAN WELDING SOCIETY. |
| | 2017 FBC-B 2204.1 WELDING |
| | 2017 FBC-B 2204.2 BOLTING. |
| | IF THERE IS ANY QUESTIONS ABOUT THE CODE REQUIREMENTS |
| | FOR THIS SECTION, PLEASE CONTACT THE CHIEF BUILDING |
| | INSPECTOR KEN CONRAD AT 561-805-6666. THANK YOU. |
| | |
| | 12B1) COMPLIED FIRE RESISTANCE OF EXISTING & NEW |
| | ELEMENTS ON THE 3 STORY BUILDING. |
| | |
| | 1B2) 2ND REQUEST. THE RESPONSE INDICATES NOTES WERE |
| | ADDED ON SHEET A-103 FOR THE RATING OF THE STEEL PORTE |
| | COCHERE WITH SHERWIN WILLIAMS FIRETEX INTUMESCENT |
| | PAINT. SHEET A-103 HAS NOT BEEN REVISED TO A VERSION 2. |
| | PLEASE PROVIDE THE INFORMATION SHEET FOR SHERWIN |
| | WILLIAMS FIRETEX INTUMESCENT PAINT. |
| | 13) 2ND REVIEW. THE RESPONSE INDICATES LIST OF DEFERRED |
| | SUBMITTALS IS FOUND ON SHEET A601. THIS SHEET HAS NEVER |
| | BEEN REVISED. W.P. B. AMENDMENT 107.3.4.2 DEFERRED |
| | SUBMITTALS. COMPONENTS AND CLADDING WERE SUBMITTED AS |
| | EXHIBITS A-E. PLEASE NOTE SINCE THE SUBMITTED PRODUCT |
| | APPROVALS ARE GOING THROUGH REVIEW ANY PRODUCT APPROVAL |
| | BEING SUBMITTED EACH PRODUCT APPROVAL WOULD THEN BE |
| | CONSIDERED SINCE THE CITY HAS PUT IN PLAN REVIEW TIME |
| | ON THE DOCUMENTS SUBMITTED AT TIME OF APPLICATION. |
| | |
| | 14-16) COMPLIED. |
| | |
| | 17) NOT APPLICABLE EXTERIOR WORK ONLY WILL RELATE TO |
| | PERMIT # 19120241 INT. REMODELING OF THE CORRIDORS AND |
| | PUBLIC SPACES. |
| | |
| | 18) NOT APPLICABLE EXTERIOR WORK ONLY WILL RELATE TO |
| | PERMIT # 19120241 INT. REMODELING OF THE CORRIDORS AND |
| | PUBLIC SPACES. |
| | |
| | 19) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, SFP & CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |