| 2019-12-31 16:23:40 | ALTERATION SECOND BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | PERMIT #19110249 |
| | |
| | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | ORIGINAL COMMENT: |
| | 1- USE OF THIS BUILDING IS NOT CLEAR. PLANS SHOW THE |
| | LAYOUT OF A SINGLE FAMILY RESIDENCE BUT ALL THE |
| | INFORMATION SHOWN UNDER THE AREA CALCULATIONS IS FOR |
| | BUSINESS TYPE USE. CLARIFY/REVISE AS REQUIRED. CLEARLY |
| | DEFINE THE USE OF THE BUILDING. SEC. 107.2.1 CITY |
| | AMENDMENTS AND SEC. 301.1 FBC-BUILDING. |
| | |
| | RESPONSE: |
| | A) PLANS SUBMITTED NOW ARE INCOMPLETE. ONLY ONE SHEET |
| | OF ARCHITECTURAL DRAWING A-000 WAS SUBMITTED AND |
| | REVISED SHEET A-100 WAS NOT SUBMITTED. NEED TO PROVIDE |
| | TWO COMPLETE SETS. SEC. 107.1 AND 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | B) THE BUILDING DATA ON SHEET A-000 STATES THAT THIS |
| | BUILDING IS CONSTRUCTION TYPE II-B. TYPICALLY SINGLE |
| | FAMILY RESIDENCES ARE CONSTRUCTION TYPE VB. PROVIDE |
| | PROOF THAT THIS A TYPE II-B BUILDING WITH |
| | NON-COMBUSTIBLE MATERIALS AS REQUIRED BY SEC. 602.2 |
| | FBC-BUILDING OR REVISE TYPE OF CONSTRUCTION AS |
| | REQUIRED. |
| | |
| | ORIGINAL COMMENT: |
| | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED |
| | BY SEC. 811.1 FBC-EXISTING BUILDING. |
| | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL |
| | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID |
| | CONFLICTS/DELAYS. |
| | |
| | RESPONSE: |
| | A) ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED |
| | AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S |
| | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 6TH EDITION |
| | (2017). |
| | |
| | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING OWNER'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | ORIGINAL COMMENT: |
| | 3-CLEARLY SPECIFY TYPE AND SIZE OF EXISTING BEDROOM |
| | WINDOWS AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY |
| | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 702.5 |
| | FBC-EXISTING BUILDING. |
| | NOTE: NEED TO VERIFY MANUFACTURER'S LARGEST STANDARD |
| | SIZE WINDOW THAT WILL FIT WITHIN THE EXISTING FRAME OR |
| | EXISTING ROUGH OPENING AND THAT WILL NOT REDUCE THE |
| | EGRESS SIZE OPENING OF EXISTING WINDOW AS REQUIRED BY |
| | SEC. 702.5. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOTE: COORDINATE WITH ITEM #1 ABOVE. |
| | INCOMPLETE PLANS SUBMITTED. |
| | |
| | |
| | ORIGINAL COMMENT: |
| | 4-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | UNABLE TO VERIFY IF PRODUCT APPROVALS WERE REVIEWED BY |
| | THE DESIGNER OF RECORD. ALSO, THERE ARE NEW PRODUCT |
| | APPROVALS SUBMITTED. PROVIDE TWO SETS OF EACH PRODUCT |
| | APPROVAL REVIEWED AND APPROVED IN WRITING BY THE |
| | ARCHITECT OF RECORD. |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND |
| | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE |
| | DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD |
| | DRAWINGS/DOCUMENTS FOR REFERENCE. |
| | |
| | |
| | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE |
| | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| | COMMENTS, |