2019-11-15 16:40:33ROOFS:
 1) NEW ROOF WILL NEED TO SHOW COMPLIANCE WITH 2017
 FBC-B 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE
 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY
 OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS
 PLEASE PROVIDE 2 SETS OF PRODUCT APPROVALS.
  
 2) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) THE STRUCTURAL SHEET S-5 INDICATES A 3/12 ROOF
 SLOPE. PLEASE NOTE THE REQUIREMENT FOR 2 LAYERS OF
 UNDERLAYMENT, SEE 2017 FBC-B TABLE 1507.1.1.
  