| Date |
Text |
| 2020-03-18 12:46:33 | REVISION SECOND BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | ORIGINAL COMMENT FROM PREVIOUS PLAN REVIEWER; |
| | 1- 405.7.4 FBC[A]CHANGE IN DIRECTION.RAMPS THAT CHANGE |
| | DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR |
| | LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 |
| | MM) MINIMUM. ADVISORY 405.7 LANDINGS. RAMPS THAT DO NOT |
| | HAVE LEVEL LANDINGS AT CHANGES IN DIRECTION CAN CREATE |
| | A COMPOUND SLOPE THAT WILL NOT MEET THE REQUIREMENTS OF |
| | THIS CODE. |
| | -PLEASE SHOW AND DIMENSION CHANGE IN DIRECTION THAT |
| | MEETS 405.7.4 FOR SIZE AND SLOPE. |
| | |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATED TO SEE REVISED |
| | REVISED SHEET A1.1.2A. REVISED SHEET A1.1.2A IS OK, BUT |
| | THERE ARE TWO RAMPS FOR THIS RETAIL SPACE. THE COMMENTS |
| | WERE FOR THE RAMP LOCATED ON THE SOUTH SIDE. PLEASE |
| | SHOW COMPLIANCE FOR THIS RAMP. |
| | |
| | ORIGINAL COMMENT FROM PREVIOUS PLAN REVIEWER; |
| | 2- 505.10.1 FBC[A]TOP AND BOTTOM EXTENSION AT |
| | RAMPS.RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE |
| | THE LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE |
| | TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO |
| | A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE |
| | CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. |
| | -PLEASE SHOW HANDRAIL EXTENSIONS AT BOTTOM OF RAMP. |
| | |
| | RESPONSE: |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATED TO SEE REVISED |
| | REVISED SHEET A1.1.2A. REVISED SHEET A1.1.2A IS OK, BUT |
| | THERE ARE TWO RAMPS FOR THIS RETAIL SPACE. THE COMMENTS |
| | WERE FOR THE RAMP LOCATED ON THE SOUTH SIDE. PLEASE |
| | SHOW COMPLIANCE FOR THIS RAMP. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | |
| | BUILDING REVIEW COMMENTS: |
| | |
| | W.P.B. PERMIT: 19101472 |
| | 2ND REVIEW: JANUARY 31, 2020 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK |
| | BELOW) |
| | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ |
| | BUILDING-PERMIT-FORMS |
| | FBC[B] = FBC BUILDING |
| | FBC[A] = FBC ACCESSIBILITY |
| | |
| | 405.7.4 FBC[A]CHANGE IN DIRECTION.RAMPS THAT CHANGE |
| | DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR |
| | LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 |
| | MM) MINIMUM. ADVISORY 405.7 LANDINGS. RAMPS THAT DO NOT |
| | HAVE LEVEL LANDINGS AT CHANGES IN DIRECTION CAN CREATE |
| | A COMPOUND SLOPE THAT WILL NOT MEET THE REQUIREMENTS OF |
| | THIS CODE. |
| | -PLEASE SHOW AND DIMENSION CHANGE IN DIRECTION THAT |
| | MEETS 405.7.4 FOR SIZE AND SLOPE. |
| | |
| | 505.10.1 FBC[A]TOP AND BOTTOM EXTENSION AT RAMPS.RAMP |
| | HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING |
| | FOR 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND |
| | BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, |
| | GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS |
| | TO THE HANDRAIL OF AN ADJACENT RAMP RUN. |
| | -PLEASE SHOW HANDRAIL EXTENSIONS AT BOTTOM OF RAMP. |
| | |