Plan Review Notes
Plan Review Notes For Permit 19101472
Permit Number 19101472
Review Stop B
Sequence Number 1
Notes
Date Text
2019-12-10 10:10:081) 404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING
 CLEARANCES AT DOORS AND GATES SHALL COMPLY
 WITH 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE
 FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE OR HINGE SIDE CLEARANCE.
 SHOW CLEARANCE FOR SIDE APPROACH ON PLANS
  
 2) PLEASE ADJUST ACCESSIBILITY RAMP TO MEET THE
 FOLLOWING BUILDING CODE PROVISIONS FOR ENCROACHMENT
 INTO THE RIGHT OF WAY.
 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN
 HEIGHT. ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
 ABOVE
 GRADE AND BELOW 8 FEET (2438 MM) IN HEIGHT SHALL BE
 PROHIBITED
 EXCEPT AS PROVIDED FOR IN SECTIONS 3202.2.1 THROUGH
 3202.2.3. DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT
 INTO
 THE PUBLIC RIGHT-OF-WAY.
 3202.2.1 STEPS. STEPS SHALL NOT PROJECT MORE THAN 12
 INCHES (305 MM) AND SHALL BE GUARDED BY APPROVED
 DEVICES NOT LESS THAN 3 FEET (914 MM) IN HEIGHT, OR
 SHALL BE
 LOCATED BETWEEN COLUMNS OR PILASTERS.
 3202.2.2 ARCHITECTURAL FEATURES. COLUMNS OR PILASTERS,
 INCLUDING BASES AND MOLDINGS, SHALL NOT PROJECT MORE
 THAN
 12 INCHES (305 MM). BELT COURSES, LINTELS, SILLS,
 ARCHITRAVES,
 PEDIMENTS AND SIMILAR ARCHITECTURAL FEATURES SHALL
 NOT PROJECT MORE THAN 4 INCHES (102 MM).