Plan Review Notes
Plan Review Notes For Permit 19101435
Permit Number 19101435
Review Stop P
Sequence Number 1
Notes
Date Text
2019-11-12 13:12:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
 1. PROVISO: AT THE PLUMBING INSPECTOR'S DISCRETION,
 SHOW THAT ANY EXISTING PLUMBING INFRASTRUCTURE,
 INCLUSIVE OF PIPING, PLUMBING FIXTURES AND APPLIANCES
 SHOWN ON THE DEMOLITION PLAN, IS CODE COMPLIANT. THIS
 MAY REQUIRE PROVIDING DOCUMENTATION OF, OPENING OF
 WALLS AND FLOORS, PRESSURE TESTS, VIDEO CAM OF BURIED
 SANITARY, ETC., AS DETERMINED BY THE PLUMBING
 INSPECTOR. PLEASE CALL TIM LARGE AT 561-805-6692 FOR
 ADDITIONAL INFORMATION OR CLARIFICATION.
 2. SEE REDLINED COMMENTS ON PLAN:
 A. SANITARY RISER DIAGRAM; PROVIDE VENT FOR WATER
 CLOSET AND SHOWER COMPLYING WITH FBC RES P3108
 B. SHOWER COMPARTMENTS LESS THAN 30" WIDE (FINISH
 DIMENSION) SHALL BE A MINIMUM 25 INCHES WIDE AND HAVE
 MINIMUM 1300 SQUARE INCHES CROSS SECTIONAL PER FBC RES
 PO2708.1.
 C. SHOWER COMPARTMENT ACCESS/EGRESS SHALL HAVE A CLEAR,
 UNOBSTRUCTED WIDTH OF NOT LESS THAN 22" PER FBC RES
 P2708.1.1.
 D. SEE SHOWER DETAIL; LINER SHALL TURN UP A MINIMUM OF
 2 INCHES FROM THE TOP DOWN TO THE THRESHOLD AT THE CURB
 SHALL BE MINIMUM OF 2 INCHES
 E. SEE SHOWER DETAIL; PROVIDE SHOWER DRAIN IN
 ACCORDANCE WITH FBC RES P2709.4.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19101435 727 KANUGA DR
  
  
  