| 2020-02-24 07:33:49 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19101431 |
| | ADD: 3515 S DIXIE HWY |
| | CONT: POWER ENTERPRISE CORP |
| | TEL: 305-216-9782 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: MON. FEB. 24TH/ 2020 |
| | ACTION: BUILDING PROVISO |
| | 1) WALK IN COOLERS ARE UNDER A SEPARATE PERMIT, WITH |
| | ASSOCIATED FEES AND REVIEWS. 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE CHAPTER 1OF THE |
| | ADMINISTRATIVE CODE SECTION 105.1 PERMITS. |
| | |
| | 2) THE PROPOSED FLOOR PLAN DOES INDICATE THE SERVICE/ |
| | CASHIERS COUNTER IS EXISTING, NO INFORMATION IS GIVEN. |
| | COMPLIANCE WITH SERVICE COUNTERS CANNOT BE ESTABLISHED |
| | CHECK IN THE FIELD. SEE THE 2017 ACCESS. CODE: |
| | CHECK WRITING SURFACES. 904.3.3. CHECK WRITING |
| | SURFACES. WHERE PROVIDED, CHECK WRITING SURFACES SHALL |
| | COMPLY WITH 902.3. |
| | WORK SURFACES. 902.3 HEIGHT. THE TOPS OF WORK SURFACES |
| | SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE |
| | THE FINISH FLOOR OR GROUND. DISPROPORTIONATE COST WAS |
| | NOT PROVIDED. |
| | |
| | 3A) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | |
| | 3B) THE DETAIL 03 THE PROPOSED ROOFING PLAN DOES |
| | PROVIDE A MIAMI-DADE NOTICE OF ACCEPTANCE (NOA) NUMBER |
| | 15-1008.01 WHICH IS EXPIRED. THERE IS A NEWER NOA FOR A |
| | REPLACEMENT, NOA: 15-1020.06 WHICH EXPIRES ON |
| | 11/06/2023. THIS NOA IS COMPRISED OF 112 PAGES. |
| | |
| | 3C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF |
| | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE |
| | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE |
| | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO |
| | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 3D) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY |
| | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES |
| | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL |
| | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF |
| | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR |
| | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN |
| | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. |
| | CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA |
| | REGISTERED PROFESSIONAL ENGINEER OR REGISTERED |
| | ARCHITECT. 1609.6.4.4.1 COMPONENTS & CLADDING. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6717 / E-MAIL: [email protected] |
| | |