| Date |
Text |
| 2020-02-28 17:34:45 | ORIGINAL COMMENT: |
| | 1-- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED |
| | ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8 |
| | ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C. |
| | ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF |
| | FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT |
| | BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS |
| | 117. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | NOTE: THERE IS A ROOFING PERMIT FOR THIS PROPERTY. BUT |
| | IS NOT CLEAR WHY THE ROOFING PERMIT WAS ISSUED BEFORE |
| | THE NEW ROOF IS INSTALLED. THIS NEEDS COORDINATION. |
| | |
| | |
| | ****************************************** |
| | |
| | ORIGINAL REVIEW COMMENTS: |
| | |
| | 1- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED |
| | ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8 |
| | ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C. |
| | ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF |
| | FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT |
| | BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS |
| | 117. |
| | |
| | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE |
| | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| | COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | 1) CERTAIN TEED NOA 15-0622.21 (FLAT ROOF) |
| | 2) CERTAIN TEED NOA 17-1211.08 (SHINGLES) |