| Date |
Text |
| 2020-02-28 17:33:37 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | ORIGINAL COMMENT: |
| | 1- PLANS SUBMITTED CALL FOR REMOVAL OF ENTIRE SECOND |
| | FLOOR AND STAIRS. NEED TO PROVIDE COMPLETE FRAMING |
| | PLANS, DETAILS AND SPECIFICATIONS FOR NEW ROOF. SPECIFY |
| | THE CURRENT CODE, WIND DESIGN CRITERIA INCLUDING THE |
| | ULTIMATE WIND LOAD AND NOMINAL WIND LOAD, BUILDING |
| | EXPOSURE, ETC. AS REQUIRED BY SEC. SEC. R301.2.1 |
| | FBC-RESIDENTIAL AND SEC. 107.3.5.3 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | 2- PLANS SUBMITTED CALL FOR A NEW LARGE SLIDING GLASS |
| | DOOR BY THE PROPOSED DINING AREA. NEED TO PROVIDE |
| | COMPLETE FRAMING PLANS, DETAILS AND SPECIFICATIONS FOR |
| | NEW SLIDING GLASS DOORS. ALSO, SPECIFY THE SIZE OF THE |
| | GLASS DOORS. SEC. R301.2.1 FBC-RESIDENTIAL AND SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | 3- PROPOSED PLANS SUBMITTED SHOW A DOOR TO BE REPLACED |
| | WITH A WINDOW AT THE REAR OF THE LIVING AREA. NEED TO |
| | PROVIDE COMPLETE FRAMING PLANS, DETAILS AND |
| | SPECIFICATIONS FOR NEW WINDOW. ALSO, SPECIFY THE TYPE |
| | AND SIZE OF THE NEW WINDOW. SEC. R301.2.1 |
| | FBC-RESIDENTIAL AND SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 4- OK. |
| | |
| | 5- OK. |
| | |
| | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | |
| | ORIGINAL COMMENT: |
| | A) SLIDING GLASS DOORS AS SHOWN ON PLANS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | B) NEW WINDOWS AS SHOWN ON PLANS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | C) OK. EXISTING EXTERIOR DOOR TO REMAIN. |
| | |
| | ORIGINAL COMMENT: |
| | 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS |
| | (INCLUDING THE ROOFING PRODUCT APPROVALS) AS REQUIRED |
| | BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | 8- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED |
| | ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8 |
| | ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C. |
| | ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF |
| | FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT |
| | BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS |
| | 117. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | NOTE: THERE IS A ROOFING PERMIT FOR THIS PROPERTY. BUT |
| | IS NOT CLEAR WHY THE ROOFING PERMIT WAS ISSUED BEFORE |
| | THE NEW ROOF IS INSTALLED. THIS NEEDS COORDINATION. |
| | |
| | ORIGINAL COMMENT: |
| | 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS. |
| | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S |
| | OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS |
| | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. PROVIDE COPY OF |
| | SIGNED CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES FOR |
| | BUILDING OFFICIAL REVIEW/APPROVAL. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | NEW COMMENT BASED ON NEW SET OF DRAWINGS SUBMITTED: |
| | |
| | 10- SPECIFY THE SIZE OF THE NEW ATTIC ACCESS. SEC. R807 |
| | FBC-RESIDENTIAL. |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE |
| | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| | COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |