| 2019-11-06 11:00:15 | FBC SIXTH EDITION (2017) - BUILDING PLAN REVIEW: 1ST |
| | REVIEW |
| | W. P. B. REVISION # 191000801 |
| | ADD: 351 PEMBROKE PLACE |
| | CONT: HEDRICK BROTHERS |
| | CONST. TYPE: 1-B |
| | OCC. TYPE: R-2 W/ A3 & B ACCESSORY OCC. |
| | SPRINKLERED |
| | |
| | BUILDING REVIEW FOR THE REVISION IS DENIED. |
| | |
| | 1) THE STRUCTURAL PLAN SHEETS FROM PABLO A. GARCIA ARE |
| | NOT DIGITALLY SIGNED. (SHEETS 026 "S00" THROUGH 065 |
| | "S511") FS 471 & FAC 61G15-23.001 |
| | |
| | 2) THERE ARE RED RECTANGLES ON SHEETS A181A AND A181B. |
| | PLEASE CLARIFY WHAT THESE REPRESENT. FBC 107.2.1 |
| | |
| | 3) THE REVISED SHEETS STILL SHOW FPS FOAM CORE ACCENT |
| | BANDS, WINDOW SILLS AND SUPPORT FEATURES. THIS WAS ONE |
| | OF THE ITEMS THAT WAS LISTED AS A REQUIREMENT FOR THE |
| | ISSUANCE OF THE MAIN BUILDING PERMIT. SEE ITEM #2 OF |
| | THE "APPROVED WITH EXCEPTIONS" LISTED BELOW. PROVIDE |
| | DOCUMENTS THAT SHOW COMPLIANCE WITH FBC 2603.5 |
| | |
| | APPROVED WITH EXCEPTIONS |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. THE |
| | FOLLOWING ITEMS WILL NEED TO BE ADDRESSED. |
| | 1) THE PLAT IS REQUIRED TO BE RE-RECORDED SHOWING THE |
| | REQUIRED CHANGES DISCUSSED AT THE P.P.C. MEETING AND A |
| | REVISED SURVEY SUBMITTED AND APPROVED BEFORE THE C.O. |
| | CAN BE ISSUED. |
| | 2) THE FOAM PLASTIC EXTERIOR TRIM THAT IS SHOWN IN THE |
| | DETAILS ON SHEET A322 IS NOT ALLOWED. REVISED PLANS |
| | COMPLYING WITH FBC 2603.5 ARE REQUIRED TO BE SUBMITTED |
| | AND APPROVED. |
| | 3) DEFERRED SUBMITTALS. FBC 107.3.4 - PROVIDE TWO SETS |
| | OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE |
| | REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE |
| | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE |
| | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING |
| | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES |
| | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW |
| | (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR |
| | TYPES.THE FOLLOWING ITEMS REQUIRE PRODUCT APPROVALS: |
| | (A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. |
| | (B) WINDOWS & MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP |
| | VENTILATORS |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. |
| | |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | |
| | |