| Date |
Text |
| 2019-12-09 15:43:39 | BUILDING REVIEW COMMENTS: |
| | |
| | W.P.B. PERMIT: 19100519 |
| | REVIEWED: DECEMBER 9, 2019 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK |
| | BELOW) |
| | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ |
| | BUILDING-PERMIT-FORMS |
| | FBC[B] = FBC BUILDING |
| | FBC[EXISTING] = FBC EXISTING BUILDING |
| | FBC[A] = FBC ACCESSIBILITY |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | |
| | 1) 109.3 FBC[AMENDED]PLEASE PROVIDE COPY OF ESTIMATE |
| | PREPARED BY THE DESIGNER TO STATE HOW VALUE OF WORK WAS |
| | DETERMINED. VALUE SHOULD INCLUDE DESIGN COSTS, |
| | DEMOLITION AND ALL REMODEL WORK THAT IS INCLUDED IN |
| | THIS PERMIT. |
| | |
| | 2) 402.2 FBC[A]PLEASE SHOW ACCESSIBLE ROUTE FROM THE |
| | ACCESSIBLE PARKING SPACE TO THE ENTRY BEING SERVED. |
| | |
| | 3) 302.1 FBC[B] GENERAL. STRUCTURES OR PORTIONS OF |
| | STRUCTURES SHALL BE CLASSIFIED WITH RESPECT TO |
| | OCCUPANCY IN ONE OR MORE OF THE GROUPS LISTED IN THIS |
| | SECTION. |
| | PLEASE PROVIDE FURTHER BREAKDOWN OF EXTISTING VS |
| | PROPOSED. THIS WILL NEED PALM BEACH COUNTY IMPACT |
| | REVIEW FOR CHANGE OF OCCUPANCY AND THEY WILL NOT HAVE |
| | ENOUGH DATA TO DETERMINE CHANGE OF OCCUPANCY. STATE |
| | EXISTING USE, SQ. FOOTAGE EACH FLOOR AND PROPOSED USE |
| | AND SQ. FOOTAGE EACH FLOOR. |
| | |
| | 4) CONSTRUCTION TYPE 1B IS BEING STATED ON SHEET 308 |
| | LS. PLEASE SHOW HOW WALL TYPES MEET THAT CONSTRUCTION |
| | TYPE. EXTERIOR WALLS AT 2 HOURS, SHOW INTERIOR BEARING |
| | WALLS AT 2 HOURS IST FLOOR AND 1 HOUR WITH SECOND FLOOR |
| | PER TABLE 601 NOTE(A). |
| | TABLE 508.4 SEPARATION OF R2 FROM A2 FLOOR CONSTRUCTION |
| | NEEDS 2 HOUR RATING AND INFILL DETAILS SHOULD INCLUDE |
| | HOW THIS IS ACHIEVED. |
| | |
| | 5) 456.3.2.2 FBC[B]PUBLIC BATHROOMS SHALL BE COMPLETELY |
| | ENCLOSED AND SHALL HAVE TIGHT-FITTING, SELF-CLOSING |
| | DOORS. |
| | ARE DOOR CLOSERS PROVIDED ON RESTROOMS? |
| | |
| | 6) SHEET 319 A SHOWS VARIOUS CALL OUTS THAT FOR SHEET |
| | A6.01 TO A6.06 AND SHEET A7.02. I DON?T SEE THESE |
| | SHEETS OR THESE DETAIL ON OTHER SHEETS. PLEASE UPDATE |
| | CALLOUTS AND ADD DETAILS/SECTIONS TO MATCH. |
| | ALSO, PROVIDE STAGE DETAILS AND MATERIALS IN THE |
| | DETAILS/SECTIONS. |
| | |
| | 7) 201.1.1 FBC[A]STAGE ACCESSIBILITY. WILL THE STAGE |
| | HAVE AN ACCESSIBLE RAMP? I DO NOT SEE EXEMPTION FOR |
| | ACCESS TO THE STAGE. |
| | |
| | PROVISOS: |
| | A) SEPARATE PERMITS REQUIRED FOR - LIGHT POLES/SITE |
| | LIGHTING, FIRE ALARM, FIRE SPRINKLER, LOW VOLTAGE, |
| | ACCESS, LANDSCAPING, IRRIGATION, PARKING LOT AND ALL |
| | OTHER ITEMS OTHER THAN BMEP |
| | B) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM |
| | SAT-SUN |
| | NO RESPONSE REQUIRED. THESE WILL BE ADDED TO THE PLANS |
| | AT FINAL STAMPING. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| | [email protected] |
| | |
| | |
| | |