| Date |
Text |
| 2019-10-11 12:19:43 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): |
| | 1. A HORIZONTAL ROLLER IS AN INAPPROPRIATE WINDOW STYLE |
| | FOR THIS STRUCTURE. PLEASE REVISE TO TWO SINGLE-HUNG |
| | WINDOWS WITH A MULLION WITH AT LEAST TWO TO FOUR INCHES |
| | WIDE. (WINDOW #1 AND #17) |
| | 2. A SINGLE-HUNG WINDOW IS INAPPROPRIATE FOR WINDOW |
| | OPENING #7 AND #9. REVISE TO A CASEMENT. THE CASEMENTS |
| | SHALL HAVE A 3 LITE PATTERN WITH TWO HORIZONTAL |
| | EXTERNAL OGEE DIMENSIONAL MUNTINS. |
| | 3. CLARIFY OPENING #12. WHAT IS CM? I DO NOT SEE A |
| | PRODUCT APPROVAL INCLUDED FOR THIS OPENING. |
| | 4. ALL SINGLE-HUNG WINDOWS WILL BE REQUIRED TO HAVE A |
| | 6/1 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL |
| | MUNTINS. PLEASE INCLUDE THIS INFORMATION ON THE PLANS. |
| | 5. ALL PROPOSED FRENCH DOORS SHALL REPLICATE THE |
| | EXISTING LITE PATTERN WITH OGEE DIMENSIONAL MUNTINS. |
| | 6. PROVIDE DETAILS OF GLASS. GLASS MUST BE CLEAR OR |
| | CLEAR GLASS WITH LOW-E. TINTED OR PRIVACY GLASS IS |
| | PROHIBITED. |
| | |
| | THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL, |
| | ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL. |
| | PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED |
| | WITH. |
| | |
| | A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR |
| | CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS |
| | IS PROHIBITED. |
| | B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE |
| | DIMENSIONAL MUNTINS. |
| | C. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL |
| | WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH |
| | WITHIN THE ORIGINAL FRAME OPENING. |
| | |
| | |
| | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, |
| | HISTORIC PRESERVATION PLANNER AT [email protected]. |
| | |
| | AARON BORNGRABER |
| | HISTORIC PRESERVATION PLANNER |
| | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES |
| | T: 561-822-1428 |
| | [email protected] |
| | |