Plan Review Notes
Plan Review Notes For Permit 19100015
Permit Number 19100015
Review Stop B
Sequence Number 2
Notes
Date Text
2020-05-13 11:20:25PLAN REVIEW - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES.
 ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 RESIDENTIAL (R3) ALTERATION/ADDITION BUILDING REVIEW
 COMMENTS ? 1ST REVIEW
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED
 BY SEC. 1106 FBC-EXISTING BUILDING AND SEC. R101.5
 FBC-ENERGY CONSERVATION. (NOT ADDRESSED)
 NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING: (NOT ADDRESSED)
 SEC. R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 3- PLANS SUBMITTED ARE MISSING SHEET S-5 LISTED ON THE
 SHEET INDEX ON SHEET D1. PROVIDE COMPLETE SET OF
 DRAWINGS, INCLUDING SHEET S-5. SEC. 107.2.1 CITY
 AMENDMENTS. (NOT ADDRESSED)
  
 4- PROPOSED FLOOR PLAN ON SHEET S1 AND FOUNDATION PLAN
 ON SHEET S4 DON'T MATCH. FOUNDATION PLAN SHOWS DOORS
 LEADING TO THE NEW PATIO AREA BUT FLOOR PLAN DON'T SHOW
 ANY DOORS. (ELECTRICAL PLAN SHOWS DOORS ALSO).
 CLARIFY/REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS. (NOT ADDRESSED)
  
 5- THERE IS ONE WINDOW ON EXISTING BEDROOM #3 THAT IS
 GOING TO BE BLOCKED TO ALLOW FOR THE ADDITION. SPECIFY
 SIZE OF EXISTING WINDOW TO REMAIN ON THE SAME BEDROOM
 TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS. SEC.
 1101.1 FBC-EXISTING BUILDING AND SEC. R310.2
 FBC-RESIDENTIAL. (NOT ADDRESSED)
  
 6- REVISE WINDOWS AND DOORS STRUCTURAL BUCK DETAILS
 SHOWN ON SHEET S1. DETAILS SHOW TAPERED BUCKS. TAPERED
 BUCKS ARE NOT ALLOWED ANYMORE AND THE BUCK NEEDS TO
 EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR
 FRAME (PROVIDE FULL SUPPORT TO THE WINDOW/DOOR FRAME).
 SEC. R609.7.2 FBC-RESIDENTIAL. (NOT ADDRESSED)
  
 7- REVISE "DESIGN DATA FOR WIND LOADS" ON SHEET S2:
 THIS BUILDING IS LOCATED IN EXPOSURE "C" NOT EXPOSURE
 "B". REVISE AS REQUIRED AND REVISE DESIGN PRESSURES
 ACCORDINGLY. AND, CLEARLY SPECIFY IF THE DESIGN
 PRESSURES SHOWN ON THE SCHEDULE ARE ULTIMATE DESIGN
 PRESSURES OR NOMINAL DESIGN PRESSURES. SEC. R301.2.1.4
 FBC-RESIDENTIAL. (NOT ADDRESSED)
  
 8- ROOF FRAMING PLAN SHOWN ON SHEET S3:
 A) IT IS MISSING THE BEAM BETWEEN THE TWO NEW BEDROOMS
 AT THE NEW PATIO AREA. PROVIDE COMPLETE DETAIL AND
 SPECIFICATIONS FOR THIS BEAM. SEC. 1101.1 FBC-EXISTING
 BUILDING AND SEC. R301.1 FBC-RESIDENTIAL. (NOT
 ADDRESSED)
  
 B) ROOF FRAMING PLAN DOESN'T MATCH ROOF PROFILE SHOWN
 ON THE EXTERIOR ELEVATIONS ON SHEET S2. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. (NOT
 ADDRESSED)
  
 9-SHEET S2:
 A) SCREEN ENCLOSURE DETAILS/SPECS SHOWN DON'T MATCH
 PLANS. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 SITE SPECIFIC INSTALLATION OF THE SCREEN ENCLOSURE THAT
 MATCHES PROPOSED INSTALLATION IN THIS ADDITION. SPECIFY
 ALL FRAMING MEMBERS AND CONNECTIONS. SEC.
 R301.2.1.1.1.1 FBC-RESIDENTIAL OR SEC. R301.2.1.1.2
 FBC-RESIDENTIAL (NOT ADDRESSED)
  
 B) WINDOW SIZE SHOWN ON ALL THE EXTERIOR ELEVATIONS
 DON'T MATCH SIZE SPECIFIED ON ON THE WINDOW SCHEDULE ON
 SHEET S1. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS. (NOT ADDRESSED)
  
 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR: (NOT ADDRESSED)
 A) EXTERIOR DOORS AS SHOWN ON PLANS.
  
 B) WINDOWS AS SHOWN ON PLANS.
  
 C) SHUTTERS IF DOORS/WINDOWS DON'T HAVE IMPACT GLAZING.
 AND PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE CITY
 SAMPLE.
  
 D) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 E) ROOF SHINGLES AS SPECIFIED ON PLANS.
  
 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. (NOT
 ADDRESSED)
  
 12- IMPACT FEES - PLANS CONVERTED TO DIGITAL. SEE
 IMPACT FEE COMMENTS
  
 13- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S (APPLIES TO OWNER/BUILDER TOO) OVERHEAD
 AND PROFIT AND DESIGN PROFESSIONAL FEES AS REQUIRED BY
 SEC. 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED TO
 $77,810. THE PERMIT FEE BALANCE IS $1855.78. COMPLETE
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 NEW COMMENTS:
  
 14. PROVIDE SOILS REPORT.
 FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE
 CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE
 REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL
 INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY
 TESTING OR ENGINEERING CALCULATIONS, SUCH
 INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED
 DESIGN PROFESSIONAL.
  
  
  