| 2020-01-14 16:14:47 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19090606 |
| | ADD: 1645 PALM BEACH LAKES BLVD. SUITE: 800 |
| | CONT: NIXON HOME IMPROVEMENTS |
| | TEL: 561-305-8215 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: TUES. JAN. 14/2020 |
| | ACTION: DENIED |
| | |
| | 1-4) COMPLIED. |
| | |
| | 5) NEW COMMENT. THE COVERSHEET & SHEET A-2 BOTH SHOW AN |
| | OCCUPANT LOAD OF 97 FOR 685 SQ. FT. OF THE BREAK ROOM. |
| | THE AREA OF THE BREAK ROOM IS CLOSER TO 24.5 X 27.5 = |
| | 674 SQ. FT./ 15 SQ. FT. PER OCC= 45 OCCUPANTS PLEASE |
| | CORRECT. SEE 2017 FBC-B TABLE 1004.1.2. ASSEMBLY WITH |
| | TABLES AND CHAIRS. 15 SQ. FT. OCCUPANT LOAD FACTOR. |
| | |
| | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |