| Date |
Text |
| 2019-10-07 10:56:48 | NFIP REVIEW - ELEVATION CERTIFICATE |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | 1&2 FAMILY PLANS EXAMINER, SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. EC FOR ACCESSORY STRUCTURE. |
| | |
| | 1A. COMPLETE SECTION C2 (E) LOWEST ELEVATION OF |
| | MACHINERY OR EQUIPMENT. |
| | 1B. ELEVATION CERTIFICATE IS BASED ON A FIRM. DESIGN |
| | FLOOD ELEVATION (DFE) OF C2 (E) SHALL BE 8.4 FEET NAVD. |
| | YOU MAY WISH TO UTILIZE THE FLOOD INSURANCE STUDY. THIS |
| | DFE WOULD BE 8.3 FEET NAVD BASED ON TRANSECT LINE 11 OF |
| | THE FIS. |
| | |
| | 2. EC FOR NEW SINGLE FAMILY RESIDENCE. |
| | |
| | 2A. THE BASE FLOOD ELEVATION (BFE) WAS ESTABLISHED BY A |
| | FLOOD INSURANCE RATE MAP. THIS ELVATION IS STATED AS 6 |
| | & 7 FEET NAVD IN SECTION B9 OF THE ELVATION CERTIFICATE |
| | (EC). THIS ELEVATION SHALL BE SET AT 7.4 FEET UNLESS A |
| | FLOOD INSURANCE STUDY (FIS) IS USED TO ESTABLISH THE |
| | BFE. |
| | 2B. THE BFE BASED ON THE FIS SHALL BE SET AT 7.3 FEET |
| | NAVD BASED ON THE PARCEL'S LOCATION TO TRANSECT LINE |
| | #11 OF THE FIS DATED OCT. 5, 2017. |
| | 2C. DUE TO THE CITY'S REQUIREMENT OF A TWO FOOT |
| | FREEBOARD THE DFE SHALL BE 9.3 FEET NAVD. |
| | 2S. TOP OF SLAB IS SHOWN AS 8.83 FEET NAVD WITH A 2 |
| | INCH ALLOWANCE FOR FLOORING. |
| | 2D. THE FINISHED FLOOR ELEVATION IS 9.0 FEET NAVD AS |
| | STATED ON THE CONSTRUCTION DRAWINGS. |
| | |
| | 3. SECTION C2(E) IS REQUIRED. |
| | |
| | |
| | |
| | |
| | |
| | |