| Date |
Text |
| 2020-03-26 10:54:02 | ADDITION AND GUEST HOUSE 19080288 AND 19090434 |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE ROOFING SYSTEMS TO BE USED. |
| | 2) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVAL FOR THE MULL BAR FOR THE CONNECTION OF |
| | THE 2 WINDOWS MARKED "W4" MASTER BEDROOM. |
| | 3) PLEASE SHOW THE WALL AND CEILING INSULATION "R" |
| | VALUE AND INSULATION TYPE TO MATCH THE ENERGY CALCS. |
| | (ENERGY CALCS NOT YET PROVIDED). |
| | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS AND |
| | EXTERIOR SWING DOORS ( DOCUMENTS PROVIDED FOR THE |
| | EXTERIOR SWING DOOR IS NOT A COMPLETE MIAMI DADE OR |
| | FLORIDA STATE PRODUCT APPROVAL) |
| | 5) DRAWING A2 - PLEASE CHECK THE WINDOW AND DOOR |
| | SCHEDULE - MARKS W4, W7 AND D1 DO NOT MATCH THE FLOOR |
| | PLAN. |
| | 6) GUEST HOUSE EGRESS DOOR WIDTH AT 32 INCHES IS NOT A |
| | WIDE ENOUGH OPENING - WIDTH NEEDS TO COMPLY WITH FBC |
| | R311.2 EGRESS DOOR. |
| | NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR |
| | EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE |
| | SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT |
| | LESS THAN 32 INCHES (813 MM) WHERE MEASURED BETWEEN THE |
| | FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 |
| | DEGREES. |
| | |