| 2019-10-22 15:01:13 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19090385 |
| | ADD: 1913 S DIXIE HWY SUITE: 400 |
| | CONT: PM DEVELOPMENT |
| | TEL: 561-889-5874 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: TUES. OCT. 22/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) COMPLIED. |
| | |
| | 2) SEMI-COMPLIED, 2.1-2.5. SHEET A1.02 SHOW NEW |
| | STOREFRONT GLAZING UNITS WITH THE WIND DESIGN CRITERIA |
| | AND STOREFRONT SYSTEMS IN V-ULT PRESSURES, THE EXPOSURE |
| | IS C. IT WOULD APPEAR THE PRESSURES GIVEN ARE B |
| | EXPOSURE PRESSURES. EXPOSURE C PRESSURES FOR A MEAN |
| | ROOF HEIGHT OF 15 FEET HAVE A MULTIPLIER OF 1.21 |
| | BUMPING THE PRESSURES UP ABOUT 6 PSF. PLEASE ALSO |
| | CONVERT THE PRESSURES TO VASD SINCE THE FIELD |
| | INSPECTORS WILL LOOKING AT THE PRODUCT APPROVALS WHICH |
| | ARE IN VASD. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 2.6 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| | BUILDING. |
| | |
| | 2.7 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| | |
| | 3-6) PROVISO/ DEFERRED SUBMITTALS. 2017 FBC-B 1609.1.2 |
| | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, |
| | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ |
| | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS ,MULLIONS |
| | (B) WINDOWS & MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, |
| | |
| | 4) PROVISO: IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY |
| | ON THE PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER |
| | OF RECORD AND BEFORE SUBMISSION TO THE BUILDING |
| | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE |
| | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, |
| | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED |
| | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE |
| | PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1 |
| | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN |
| | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. |
| | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH |
| | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM |
| | LOADS AND SPACING USED IN THE TESTS. |
| | |
| | 5) PROVISO: W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | 6) PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. FOR THE |
| | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE |
| | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT |
| | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE |
| | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A |
| | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL |
| | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE |
| | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE |
| | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION |
| | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. |
| | |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. |
| | |
| | 7) COMPLIED. |
| | |
| | 8) NEW COMMENT. SHEET LS1.01 & A1.01 BOTH SHOW A NEW |
| | FRONT ENTRY DESIGN WITH A DOUBLE DOOR LOBBY/ VESTIBULE |
| | SYSTEM. WITH THIS TYPE OF SYSTEM YOU STILL WILL NEED TO |
| | SHOW COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE |
| | 404.2.6 DOORS IN SERIES AND FIGURE 404.2.6. THE |
| | DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES |
| | AND GATES IN SERIES SHALL BE 48 INCHES MINIMUM PLUS THE |
| | WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. |
| | |
| | 9) NEW COMMENT. SHEET LS1.01 & A1.01 BOTH SHOW A NEW |
| | FRONT ENTRY DESIGN WITH STRUCTURAL WING WALLS AND |
| | CEILING THAT WILL BE SUBJECT TO EXTERIOR WEATHER |
| | CONDITIONS RAIN AND WIND. PLEASE PROVIDE THE MATERIALS |
| | THIS EXTERIOR WALL & CEILING WILL BE CONSTRUCTED FROM. |
| | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1 THE ADMINISTRATIVE CODE 107.2.1.2 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 10) THE NEWLY FORM SET OF PLANS ARE NOT COMPLETE, |
| | MISSING THE COVERSHEET WITH INDEX OF DRAWINGS AND THE |
| | D.01 DEMOLITION SHEET AND NOTES. 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 THE |
| | ADMINISTRATIVE CODE 107.2.1.2 ADDITIONAL INFORMATION IS |
| | REQUIRED. |
| | |
| | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |