| 2019-09-11 16:37:49 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) SHEET A 219 - THERE ARE SYMBOLS; CIRCLES, SQUARES |
| | AND OCTAGONS, WITH NUMBERS IN THEM BUT NO LEGEND |
| | IDENTIFYING WHAT THEY REPRESENT. |
| | |
| | PLEASE REVIEW AND CLARIFY OF PROVIDE THE APPLICABLE |
| | LEGEND. |
| | |
| | |
| | |
| | 2) SHEET A 219 - ELEVATOR EXIT LOBBY DOOR EXIT 1971, IS |
| | NOT INDICATED WITH HARDWARE IN COMPLIANCE WITH NFPA |
| | 101, CH 7 MEANS OF EGRESS. |
| | |
| | 7.4.1.6 ELEVATOR LANDING AND LOBBY EXIT ACCESS. |
| | 7.4.1.6.1 EACH ELEVATOR LANDING AND LOBBY SHALL HAVE |
| | ACCESS TO AT |
| | LEAST ONE EXIT. |
| | 7.4.1.6.2 THE ELEVATOR LANDING AND LOBBY EXIT ACCESS |
| | REQUIRED BY |
| | 7.4.1.6.1 SHALL NOT REQUIRE THE USE OF A KEY, A TOOL, |
| | SPECIAL |
| | KNOWLEDGE, OR SPECIAL EFFORT, UNLESS PERMITTED BY |
| | 7.4.1.6.3. |
| | 7.4.1.6.3 DOORS SEPARATING THE ELEVATOR LOBBY FROM THE |
| | EXIT ACCESS |
| | REQUIRED BY 7.4.1.6.1 SHALL BE PERMITTED TO BE |
| | ELECTRONICALLY LOCKED |
| | IN ACCORDANCE WITH 7.2.1.6.3. |
| | |
| | |
| | 3) THERE DOES NOT APPEAR TO BE A DOOR SCHEDULE |
| | INDICATING EACH DOOR LOCATION, TYPE, HARDWARE GROUP, |
| | LOCKS & LATCHES , ETC. |
| | |
| | SHEET A 219 HAS A DOOR TYPE SCHEDULE AND HARDWARE |
| | GROUPS BUT NO CORRESPONDING DOOR LOCATIONS. |
| | |
| | PLEASE REIVEW AND PROVIDE. |
| | |
| | |
| | 4) SHEET A 219 - THERE IS AN INDICATION OF DOOR |
| | SECURITY EQUIPMENT. |
| | |
| | ALL ACCESS CONTROL SHALL BE UNDER SEPARATE PERMIT, SHOP |
| | DRAWINGS, EQUIPMENT SPECS AND COMPLY WITH NFPA 101, CH |
| | 7 , MEANS OF EGRESS, WERE APPLICABLE. |
| | |
| | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT AND |
| | COMPLIANCE. |
| | |
| | |
| | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |