| 2019-11-08 12:43:35 | BUILDING REVIEW COMMENTS: |
| | |
| | W.P.B. PERMIT: 19090022 |
| | 2 ND REVIEW: NOVEMBER 8, 2019 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK |
| | BELOW) |
| | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ |
| | BUILDING-PERMIT-FORMS |
| | FBC[B] = FBC BUILDING |
| | FBC[EXISTING] = FBC EXISTING BUILDING |
| | FBC[A] = FBC ACCESSIBILITY |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19090022 |
| | ADD: 2751 S. DIXIE HWY. |
| | CONT: RED DOOR CONSTRUCTION LLC |
| | TEL: 786-535-1006 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | DATE: TUES. OCT. 16/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) OK-PROVISO: PROVIDE RECORDED UNITY OF TITLE WHEN |
| | FINALIZED |
| | |
| | 2)- 2B OK |
| | |
| | 3A) THE 1ST FLOOR LIFE SAFETY PLAN SHOWS 2 LOUNGES AN |
| | ACTIVE LOUNGE # 147 OF 912 SQUARE FEET AND A PASSIVE |
| | LOUNGE # 149 WITH 1925 SQUARE FEET. THE ACTIVE LOUNGE |
| | IS SHOWN AS A BUSINESS USE WHEREAS THE PASSIVE LOUNGE |
| | IS BEING SHOWN AS AN ASSEMBLY USE. IT WOULD APPEAR THAT |
| | BOTH LOUNGES ARE AN ASSEMBLY OCCUPANCY. IT WOULD APPEAR |
| | THIS IS A MIXED USE 1ST FLOOR WITH BUSINESS AND |
| | ASSEMBLY OCCUPANCIES RATHER THAN ACCESSORY OCCUPANCIES, |
| | SEE SECTION 508.2.3 OF THE 2017 FBC-B. WHEN THE PASSIVE |
| | AND ACTIVE SQUARE FOOTAGE ARE COMBINED THEY ADD UP TO |
| | 2837 SQ. FEET OR OVER 10 % OF THE 1ST FLOOR AREA. |
| | -2ND REVIEW- |
| | 508.2.3 FBC[B]THE RESPONSE INCLUDES CALCULATION OF 10 |
| | PERCENT BASED ON INTERIOR SPACE AND EXTERIOR SPACE. THE |
| | 10 PERCENT SHOULD BE BASED OFF THE MAIN OCCUPANCY AND |
| | THE EXTERIOR COVERED AREA IS A SEPARATE OCCUPANCY THAT |
| | MEETS ITS OWN SEPARATION REQUIREMENTS. IT SHOULD NOT BE |
| | PART OF THE CALCULATION OF MAIN OCCUPANCY. |
| | |
| | 3B) THE DESIGNER OF RECORD WILL NEED TO PROVIDE DESIGN |
| | CRITERIA FOR EITHER NON-SEPARATED OCCUPANCIES UNDER |
| | 508.3 OR 508.4 SEPARATION OF OCCUPANCIES IN COMPLIANCE |
| | WITH 508.2.4. |
| | 2ND REVIEW- |
| | -ASSESSORY MAY ONLY APPLY TO ONE OF THE LOUNGES, SO |
| | REVIEW AND ADJUST AS NEEDED. |
| | |
| | 3C)- 12 OK |
| | |