| 2019-09-16 15:52:49 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | NFPA 54 = NATIONAL FUEL GAS CODE |
| | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE |
| | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE |
| | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 |
| | NFPA 99 = HEALTH CARE FACILITIES CODE |
| | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | |
| | 1ST REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | |
| | |
| | 1. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS |
| | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW |
| | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL |
| | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST |
| | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW |
| | APPROVAL. |
| | |
| | A. PER FBC ACC 213.3.6, THE BATHROOM SHOWER, ONE OF THE |
| | TWO FOAT TANK ROOMS AND THE OPEN FLOAT TUB ROOM SHALL |
| | COMPLY WITH FBC ACC 608. |
| | |
| | 1) PROVIDE CLEAR FLOOR SPACE ON PLAN VIEW SHOWING |
| | COMPLIANCE WITH FBC ACC SECTION 305. |
| | 2) PROVIDE A DETAIL (ELEVATION) OF THE SHOWER SHOWING |
| | COMPLIANCE WITH FBC ACC SECTION 608. |
| | |
| | B. WATER CLOSET SHALL BE 16" MINIMUM AND 18" MAXIMUM, |
| | CENTERLINE TO SIDE WALL PER FBC ACC 604.2 AND THE REAR |
| | WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG MINIMUM |
| | AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 |
| | INCHES (305 MM) MINIMUM TO THE WALL SIDE AND 24 INCHES |
| | (610 MM) MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2. |
| | C. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| | NOT ALLOW CONTINUOUS PAPER FLOW PER FBC ACC 604.7. |
| | |
| | 2. WHAT IS THE OPEN FLOAT TUB AND HOW IS WATER SUPPLIED |
| | TO IT? |
| | 3. HOW ARE THE FLOAT TANKS DRAINED? DO THE HOSE BIBS |
| | PROVIDE WATER FOR THE FLOAT TANKS? |
| | 4. PER WPB FBC 107.2.1, PROVIDE MANUFACTURERS |
| | SPECIFICATION/CUT SHEETS FOR FLOAT TANKS AND OPEN FLOAT |
| | TUB. |
| | 5. RE: SANITARY ISOMETRIC; A SHOWER IS INDICATED WHERE |
| | THE OPEN FLOAT TUB SHOULD BE. PLEASE CLARIFY. |
| | 6. SHOW LOCATION OF SHUT OFF VALVES FOR STACKABLE |
| | WASHER/DRYER COMBO TO SHOW COMPLIANCE WITH FBC PL |
| | 606.3.. |
| | |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |
| | 19081275 5612 S DIXIE HWY |
| | |
| | |