| 2019-09-13 14:41:29 | 1ST REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. PROVIDE OVERALL DIMENSIONS FOR THE BATHROOM AND SHOW |
| | DIMENSIONS ON THE CLEAR FLOOR SPACE FOR ACCESSIBILITY. |
| | PER WPB AMEND TO FBC 107.2.1 ADDITIONAL INFORMATION |
| | REQUIRED |
| | |
| | 2. SHOW THE COMPLIANCE WITH THE FOLLOWING FBC ACC |
| | 602.1 GENERAL. DRINKING FOUNTAINS SHALL COMPLY WITH 307 |
| | AND 602. |
| | |
| | 602.2 CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR |
| | OR GROUND SPACE COMPLYING WITH 305 POSITIONED FOR A |
| | FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE |
| | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 602.4 SPOUT HEIGHT. SPOUT OUTLETS SHALL BE 36 INCHES |
| | (915 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND |
| | |
| | 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. SPOUT |
| | OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS |
| | SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 INCHES (1090 |
| | MM) MAXIMUM ABOVE THE FINISH FLOOR |
| | |
| | 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| | 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM |
| | THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| | PERPENDICULAR FROM THE REAR WALL. |
| | |
| | 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42 |
| | INCHES (1065 MM) LONG MINIMUM, LOCATED 12 INCHES (305 |
| | MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES |
| | (1370 MM) MINIMUM FROM THE REAR WALL. |
| | |
| | 604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 |
| | INCHES (915 MM) LONG MINIMUM AND EXTEND FROM THE |
| | CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) |
| | MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON |
| | THE OTHER SIDE. |
| | |
| | 604.7 DISPENSERS. TOILET PAPER DISPENSERS SHALL COMPLY |
| | WITH 309.4 AND SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 |
| | INCHES (230 MM) MAXIMUM IN FRONT OF THE WATER CLOSET |
| | MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET |
| | OF THE DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM |
| | AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR |
| | |
| | 604.4 SEATS. THE SEAT HEIGHT OF A WATER CLOSET ABOVE |
| | THE FINISH FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM |
| | AND 19 INCHES (485 MM) MAXIMUM MEASURED TO THE TOP OF |
| | THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A |
| | LIFTED POSITION. |
| | |
| | 603.3 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR |
| | COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF |
| | THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM |
| | ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED |
| | ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH |
| | THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES |
| | (890 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING |
| | WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE |
| | AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED |
| | WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER |
| | SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE |
| | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES (840 MM) |
| | MINIMUM AND 36 INCHES (915 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |