| Date |
Text |
| 2023-01-10 15:45:51 | INSUFFICIENT |
| | |
| | HOTWIRE P446 N. TERRACE & 41ST STREET |
| | |
| | REPEAT COMMENT: IN ACCORDANCE WITH SECTIONS 78-402(B) |
| | AND 78-411(B)(4) OF THE CITY OF WEST PALM BEACH CODE OF |
| | ORDINANCES, THE CITY OF WEST PALM BEACH IS REQUESTING |
| | THAT THIS PROPOSED SMALL WIRELESS FACILITY BE MOVED TO |
| | ANOTHER LOCATION IN THE RIGHT-OF-WAY AND PLACED ON AN |
| | ALTERNATIVE UTILITY POLE OR ON A NEW UTILITY POLE TO BE |
| | INSTALLED WITHIN THE RIGHT-OF-WAY. PLEASE NOTE THAT |
| | THIS IS A RESIDENTIAL NEIGHBORHOOD AND SECTION |
| | 78-411(B)(2) STATES THAT WIRELESS FACILITIES SHALL BE |
| | LOCATED ON THE OPPOSITE SIDE OF THE RIGHT-OF-WAY FROM |
| | RESIDENTIAL STRUCTURES AND NOT DIRECTLY IN FRONT OF A |
| | RESIDENTIAL STRUCTURE. |
| | |
| | PLEASE REMEMBER THAT POLES SHALL BE LOCATED SO AS TO |
| | ALIGN WITH EXISTING POLES IN THE RIGHT-OF-WAY AND HAVE |
| | EQUAL SETBACK DISTANCES WITH EXISTING POLES FROM THE |
| | CURBLINE OF THE RIGHT-OF-WAY. |
| | |
| | PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| | DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| | OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| | COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| | THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| | REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| | HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| | THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| | NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| | APPROVED. |
| | |
| | 1) REPEAT COMMENT: PROVIDE A SURVEY, PREPARED BY A |
| | FLORIDA LICENSED SURVEYOR, THAT SHOWS: |
| | |
| | A. THE POLE LOCATION, THE RIGHT-OF-WAY LINE, AND THE |
| | UNDERGROUND ELECTRIC TO THE POLE SO THAT STAFF CAN |
| | VERIFY THAT THE UNDERGROUND ELECTRIC AND ANY REQUIRED |
| | BORE PITS AND HANDHOLES ARE WITHIN THE RIGHT-OF-WAY AND |
| | WHICH JURISDICTION'S RIGHT-OF-WAY THEY ARE IN. |
| | B. THE HEIGHT OF THE PROPOSED POLE AND THE HEIGHT OF |
| | THE UTILITY POLE WITHIN THE RIGHT-OF-WAY THAT IS BEING |
| | USED TO ESTABLISH THE HEIGHT OF THE PROPOSED WIRELESS |
| | COMMUNICATION FACILITY POLE. |
| | C. THE UNDERGROUND UTILITIES FOR THE EXTENT OF THE |
| | PROJECT, INCLUDING THE UNDERGROUND POWER ROUTE. |
| | D. ABOVEGROUND FEATURES, INCLUDING TREES. |
| | E. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN |
| | THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S |
| | EXISTING FACILITIES - NO INFORMATION ON EXISTING |
| | FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE |
| | PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO |
| | FACILITIES, THIS SHALL BE NOTED ON THE SURVEY. |
| | |
| | 2) ENGINEERING PLAN (BASED OFF THE SURVEY REQUIRED IN |
| | COMMENT #1) |
| | |
| | A. REPEAT COMMENT: THE ENGINEERING PLAN WAS SUBMITTED |
| | AT A 1 INCH = 30 FOOT SCALE, WHICH DOES NOT COMPLY WITH |
| | THE CITY CODE SCALE REQUIREMENT OF 10FT, 20FT, OR 40FT |
| | SCALE. PROVIDE THE PLANS AT THE REQUIRED SCALE. |
| | B. SHOW THE UNDERGROUND POWER ROUTE ON THE ENGINEERING |
| | PLAN. |
| | C. PROVIDE THE CROSS SECTION OF THE UNDERGROUND |
| | ELECTRIC SO THAT STAFF CAN VERIFY THAT THE BORE IS DEEP |
| | ENOUGH TO AVOID EXISTING UTILITIES AND DAMAGING THE |
| | ROOT SYSTEMS OF THE TREES OVER THE ELECTRIC PATH. |
| | |
| | 3) THANK YOU FOR SHOWING AS STEALTH POLE DESIGN. PLEASE |
| | PROVIDE VERIFICATION THAT THE METER AND ALL EQUIPMENT |
| | WILL BE HOUSED WITHIN THE POLE. THE POLE DETAIL SHEET |
| | DOES NOT SHOW A METER LOCATION. |
| | |
| | 4) REPEAT COMMENT: RADIO FREQUENCY INTERFERENCE - NO |
| | INFORMATION WAS PROVIDED THAT THE PROPOSED FACILITIES |
| | WILL NOT CAUSE RADIO FREQUENCY INTERFERENCE WITH THE |
| | CITY'S PUBLIC SAFETY COMMUNICATIONS EQUIPMENT. PROVIDE |
| | A STATEMENT REGARDING RADIO FREQUENCY INTERFERENCE. |
| | |
| | 5) REPEAT COMMENT: PUBLIC UTILITY LETTERS - PROVIDE A |
| | COPY THE UTILITY LETTERS OF NO OBJECTION FROM THE |
| | PROVIDERS THAT ARE SHOWN ON THE SURVEY WITH FACILITIES |
| | IN THE AREA. THE ENGINEERING PLAN SHOWS FLORIDA POWER |
| | AND LIGHT IN THE AREA, BUT THE NO OBJECTION LETTER FROM |
| | THEM HAS NOT BEEN PROVIDED. |
| | |
| | 6) THE RIGHTS-OF-WAY IN THIS AREA ARE CONTROLLED BY |
| | WEST PALM BEACH. REMOVE THE REFERENCES TO PALM BEACH |
| | COUNTY FROM THE PLANS. |
| | |
| | CONTACT ERIC SCHNEIDER @ 561-822-1446 |
| | [email protected] |
| | |