| Date |
Text |
| 2019-08-20 12:19:02 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM |
| | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) |
| | 805-6724 |
| | [email protected] |
| | |
| | 1ST REVIEW: FBC 2017 6TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A |
| | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO |
| | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT |
| | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE |
| | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: |
| | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| | UILDING-PERMIT-FORMS |
| | |
| | 1.FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF |
| | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT THE |
| | FOLLOWING; COLUMN HEADING ?SHUTTER GLASS SEPARATION?; |
| | PROVIDE INFORMATION FROM SHEET 11 FL1850. COLUMN |
| | HEADING ?MINIMUM EDGE DISTANCE?; PROVIDE INFORMATION |
| | FROM SHEET 13 FL1850. COLUMN HEADING ?ANCHOR SPACING?; |
| | PROVIDE INFORMATION FROM PAGES 12-15 FL1850. EXAMPLE: |
| | POURED CONCRETE, MOUNTING TYPE L, MAXIMUM SPAN 8?-0?, |
| | 40 (PSF), USING TAPCON WITH ADVANCED THREADFORM |
| | TECHNOLOGY THE MAXIMUM ANCHOR SPACING IS 5?. |
| | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE |
| | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON |
| | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF |
| | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON |
| | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). |
| | REDUCE ANCHOR SPACING BY MUTIPLYING SPACING SHOWN ON |
| | SCHEDULE BY THE FACTOR. |
| | |