Plan Review Notes
Plan Review Notes For Permit 19071357
Permit Number 19071357
Review Stop ENG
Sequence Number 1
Notes
Date Text
2019-07-26 08:42:08PASSED WITH PROVISOS:
  
 1) CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB
 CONSTRUCTION STANDARD DETAIL GC-6 (WHEN DISTANCE
 BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER),
 OR STANDARD DETAIL GC-7 (WHEN DISTANCE BETWEEN CURB OR
 EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD
 DETAIL IS REQUIRED, SEE LINK BELOW: HTTP://WPB.ORG/DEPA
 RTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICA
 TIONS
  
 2) IF USING PAVERS IN THE APRON AREA OF THE PROPOSED
 DRIVEWAY, YOU MUST EXECUTE A PAVER DRIVEWAY AGREEMENT,
 WHICH CAN BE OBTAINED HERE: HTTP://WPB.ORG/DEPARTMENTS/
 ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS.
 THE AGREEMENT MUST BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE - RECORDING DEPT. 4.25. A RECORDED COPY OF
 THIS DOCUMENT SHOULD BE FAXED TO (561) 494-1116.
 ATTENTION: DRIVEWAY REVIEWER. DOCUMENT NEEDS TO BE
 RECORDED PRIOR TO FINAL SIGN OFF.
  
 3) FOR DRIVEWAYS WITHIN THE CITY OF WPB WE HIGHLY
 RECOMMEND THE USE OF ASTM C-1272 STANDARD FOR PAVERS,
 FOR THIS TYPE OF SPECIFICATION THE THICKNESS FOR PAVERS
 IS RECOMMEND TO BE 3-1/8". (RIGHT-OF-WAY PORTION OF
 DRIVEWAY APRON). "F" TYPE PAVERS ARE RECOMMENDED WHEN
 USING A FLEXIBLE BASE (SAND AGGREGATE, COMPACTED GRAVEL
 BASE, ETC.FOR TYPE "F" PAVERS SHOULD BE NOT LESS THAN 2
 5/8" IN THICKNESS. REF: ARCHITECTURAL GRAPHIC STANDARDS
 FOR RESIDENTIAL CONSTRUCTION, 2ND EDITION.
  
 4) CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE
 INFO ON "CALL BEFORE YOU DIG", GO TO
 HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY
 DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE,
 CHAPTER 556.)
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved