Plan Review Notes
Plan Review Notes For Permit 19071032
Permit Number 19071032
Review Stop P
Sequence Number 1
Notes
Date Text
2019-08-15 13:56:52CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54= STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMEMTS: DENIED
 AS REQUIRED BY FBC PL 404 AND FBC EX 806.1, THE
 FOLLOWING COMMENTS CONCERNING ACCESSIBILITY ARE
 APPLICABLE.A PLUMBING PERMIT WILL NOT BE ISSUED WITHOUT
 A SATISFACTORY RESOLUTION.
 1. PLAN SHEET TS: PER WPB FBC 107.2.1, INCLUDE IN
 BUILDING DEPARTMENT NOTES; CODE INFORMATION ?FLORIDA
 BUILDING CODE: 2017 ACCESSIBILITY ?
 2. PLAN SHEET TS: PER WPB FBC 107.2.1, STATE WHAT THE
 ACTUAL OCCUPANCY IS AND PROVIDE THE OCCUPANT LOAD. THEN
 BASED UPON THAT INFORMATION, LIST THE MINIMUM PLUMBING
 FIXTURE REQUIREMENTS TO SHOW COMPLIANCE WITH FBC PL
 403.1 AND TABLE 403.1. A COMPLETE REVIEW CANNOT BE MADE
 AT THIS TIME.
 3. PLAN SHEET TS ACCESSIBILITY REQUIREMENTS AND PLAN
 SHEET A-6: PER WPB FBC 107.2.1, CORRECT OR PROVIDE THE
 FOLLOWING AS APPLICABLE:
 4. TOILETS DETAIL ON TS IS NOT REPRESENTATIVE OF THE
 TOILET ROOMS NOTED ON A-2 AND A-6. PER WPB FBC 107.2.1,
 PROVIDE ACCURATE DEPICTION.
 5. THE CENTERLINE OF THE WHEEL CHAIR ACCESSIBLE WATER
 CLOSET SHALL BE 16? MINIMUM/18? MAXIMUM FROM THE SIDE
 WALL PER FBC ACC 604.2.
 6. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM)
 LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM
 THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM
 FROM THE REAR WALL PER FBC ACC 604.5.1
 7. THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM)
 LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE
 WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND
 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE PER FBC
 ACC604.5.2.
 8. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR PER FBC
 ACC 604.7.
 9. PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES (840 MM) MINIMUM AND 36
 INCHES (915 MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED
 TO THE TOP OF THE GRIPPING SURFACE
 10. PER FBC ACC 609.4, LAVATORIES SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 11. PER WPB FBC 107.2.1, PROVIDE DETAILS OF SHOWER TO
 COMPLY WITH FBC ACC 608.
 12. PLAN SHEET A-2: PER WPB FBC 107.2.1, DESIGNATE ADA
 RESTROOM(S)/BATHROOM(S).
 13. PLAN SHEET A-2: PER WPB FBC 107.2.1, PROVIDE ROOM
 DIMENSIONS, CLEAR FLOOR SPACES AND TURNING RADIUS FOR
 WEST BUILDING EXISTING RESTROOM 2 TO COMPLY WITH FBC
 ACC 304 AND 305. THE LAVATORY SHALL NOT INFRINGE UPON
 THE CLEAR FLOOR SPACE OF THE WATER CLOSET. COMPLY WITH
 FBC ACC 604.3.1 AND 604.3.2.
 14. PLAN SHEET A-2: PER WPB FBC 107.2.1, PROVIDE CLEAR
 FLOOR SPACES INCLUDING THE SHOWER FOR EAST BUILDING NEW
 H.C. BATHROOM TO COMPLY WITH FBC ACC 304 AND 305.
 15. PLAN SHEET A-2 AND A-6: PER WPB FBC 107.2.1, AS
 REQUIRED BY FBC EX 806.1 AND FBC ACC 213.3, WHERE
 BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE BATHTUB
 COMPLYING WITH 607 OR AT LEAST ONE SHOWER COMPLYING
 WITH 608 SHALL BE PROVIDED.
 16. PLAN SHEET A-2: PER WPB FBC 107.2.1, PROVIDE CLEAR
 FLOOR SPACE FOR WEST BUILDING KITCHEN TO COMPLY WITH
 FBC ACC 304 AND 305.
 17. PLAN SHEET A-6; DETAIL 1: SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND PER FBC ACC 606.3.
  
 ADDED COMMENTS
 1. WATER HEATER IN WEST BUILDING NOTED ON A-1 AS REMOVE
 AND RELOCATE AS NOTED ON THE PLUMBING PLANS IS NOT
 SHOWN ON THE PLUMBING PLANS OR ON A-2.PER WPB FBC
 107.2.1, PLEASE CLARIFY.
 2. RELOCATED WATER HEATER SHALL CONFORM TO FBC EC
 C404.2
 3. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR RELOCATED
 WATER HEATER IN EAST BUILDING, CONFORMING TO THE
 REQUIREMENTS OF FBC PL SECTIONS 503, 504 AND 607.3.
 PROVIDE SHEDULE NOTING MANUFACTURER, STORAGE CAPACITY
 AND ELECTRICAL CHARACTERISTICS.
 4. PER FBC PL 416.5, PROVIDE TEMPERED WATER TO
 LAVATORIES THROUGH A TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OS CSA B124.3
 5. PER FBC PL 424.3 PROVIDE SHOWER CONTROL VALVE WHICH
 IS PRESSURE BALANCED PB, THERMOSTATIC MIXING (TM) OR
 COMBINATION PB/TM VALVE TYPES WITH HIGH TEMPERATURE
 LIMITING STOP.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19071032 1014 N OLIVE AVE
  
  


Account Summary | Usage Policy | Privacy Policy