| Date |
Text |
| 2019-09-11 15:30:28 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 |
| | 6TH EDITION |
| | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE |
| | FS = FLORIDA STATUTES |
| | FAC = FLORIDA ADMINISTRATIVE CODE |
| | |
| | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. |
| | |
| | 1. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT |
| | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 |
| | 2. PROVIDE LOCATION OF ELECTRICAL PANEL ON PLAN TO |
| | CONFIRM CODE COMPLIANCE. WPB FBC 107.2.1 |
| | 3. PROVIDE CLARIFICATION ON LOCATION OF ELECTRICAL |
| | PANEL IN RELATION TO THE ELECTRICAL SERVICE. CONDUCTORS |
| | THAT ARE NOT PROTECTED BY A MAIN BREAKER OR DISCONNECT |
| | ARE NOT PERMITTED TO RUN THROUGH THE DWELLING UNIT. |
| | PROVIDE EITHER A MAIN ON THE OUTSIDE OF THE HOME, OR |
| | INSTALL THE CONDUCTORS UNDER THE SLAB IF REQUIRED PER |
| | CODE. IF A MAIN DISCONNECT IS INSTALLED ON THE EXTERIOR |
| | OF THE DWELLING, THAN CODE REQUIRES AN EQUIPMENT |
| | GROUNDING CONDUCTOR IN THE CONDUIT TO THE INTERIOR |
| | PANEL. PROVIDE CORRECTIONS AS NEEDED. NEC 230.70, |
| | 250.122; FBC RE E3601.6 |
| | |
| | END OF COMMENTS. |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY |
| | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED |
| | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD |
| | SHEETS. |
| | |
| | SINCERELY, |
| | |
| | JOHN PEARSON |
| | ELECTRICAL PLANS EXAMINER |
| | 561-805-6746 |
| | [email protected] |
| | |