2019-12-16 06:57:48GAS 2ND REVIEW**DENIED**19070210** IT HELPS TO SUPPLY A
 NARRATIVE WHEN RESPONDING TO THE COMMENTS
  
 1) YOU ARE PROVIDING MANUFACTURE MANUALS FOR NEW L.P
 TANK BUT CALL OUT TANK AS EXISTING. PLEASE CLARIFY 2ND
 REQUEST. FBC 107.2.1
 2) VALUE SEEMS LOW. PLEASE PROVIDE A SIGNED BONA FIDE
 CONTRACT. VALUE MUST INCLUDE ALL NEW EQUIPMENT. FBC
 109.3
 3) PROVIDE MANUFACTURE MANUALS SHOWING REGULATORS
 COMPLY WITH FBC-GAS AND ARE ANSI Z21.80 APPROVED.
 FBC-GAS 410.1
 4) PLEASE PROVIDE WHICH MODEL OF GAS REGULATOR YOU ARE
 USING. MANUFACTURE MANUAL PROVIDE SHOWS 8 DIFFERENT
 MODELS. FBC 107.2.1
 5) PROVIDE MANUFACTURES INSTALL MANUALS FOR ALL NEW
 EQUIPMENT BEING INSTALLED. FBC 107.3.5 2ND REQUEST.
 6) PROVIDE SURVEY SHOWING LOCATION OF EQUIPMENT ON
 PROPERTY INCLUDING NEW L.P TANK. FBC 107.3.5 2ND
 REQUEST
 7) SHOW THE DISTANCE FROM THE 2PSI REGULATORS TO ALL
 APPLIANCES. FBC-RES GAS G2413.4.1, G2413.4.2. 2ND
 REQUEST
 8) WHERE CONNECTED TO RIDGED PIPING A UNION SHALL BE
 INSTALLED WITHIN 1 FOOT OF EITHER SIDE OF THE MP
 REGULATOR. FBC-GAS 410.2. 2ND REQUEST.
  