| 2020-02-04 07:28:29 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19070081 |
| | ADD: 5601 GREENWOOD AVE. |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: ?????????????????? |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 3RD REVIEW |
| | DATE: TUES. FEB. 04/ 2020 |
| | ACTION: PASSED |
| | |
| | 1) NOTICE ONLY. WALK-IN COOLERS REQUIRE THEIR OWN |
| | PERMIT, REVIEW AND ASSOCIATED FEES. |
| | |
| | 2) NOTICE ONLY. TRUSS LAYOUT AND ENGINEERING SHEETS ARE |
| | TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF RECORD, |
| | SHOP DRAWING STAMP OF APPROVAL AFFIXED BEFORE BEING |
| | SUBMITTED TO THE BUILDING DEPARTMENT. |
| | |
| | 3) ROOFING PROVISO: FROM THE DESIGNER OF RECORD: |
| | SUB-SYSTEM NO. 32 IS WHAT WE ARE USING IN THE NEMO |
| | REPORT. THE SYSTEM IS AS FOLLOWS: SLOPED PLYWOOD |
| | DECK-MECHANICALLY ATTACHED DENSDECK PRIME 4X8 SHEETS |
| | USING #12 SCREWS /3" INSULATION PLATES USING 18 |
| | FASTENERS PER BOARD IN THE FIELD, 27 IN THE PERIMETER |
| | AND 36 IN THE CORNERS. ADHERE TPO SET IN SOLVENT BASED |
| | BONDING ADHESIVE. ONCE A GENERAL CONTRACTOR IS |
| | SELECTED, THE GC WILL ENGAGE THE ROOFING SUB-CONTRACTOR |
| | TO PRODUCE SIGNED AND SEALED SHOP DRAWINGS, INCLUDING |
| | CALCULATIONS. THE STRUCTURAL ENGINEER WILL REVIEW AND |
| | WILL AFFIX THEIR SHOP DRAWING STAMP BEFORE BEING |
| | SUBMITTED TO THE BUILDING DEPARTMENT. |