| Plan Review Notes For Permit 19070081 |
| Permit Number |
19070081 |
|
| Review Stop |
R |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-12-10 13:59:26 | ROOFING PROVISO: FROM THE DESIGNER OF RECORD: | | | SUB-SYSTEM NO. 32 IS WHAT WE AARE USING IN THE NEMO | | | REPORT. THE SYSTEM IS AS FOLLOWS: SLOPED PLYWOOD | | | DECK-MECHANICALLY ATTACHED DENSDECK PRIME 4X8 SHEETS | | | USING #12 SCREWS /3" INSULATION PLATES USING 18 | | | FASTENERS PER BOARD IN THE FIELD, 27 IN THE PERIMTER | | | AND 36 IN THE CORNERS. ADHERE TPO SET IN SOLVENT BASED | | | BONDING ADHESIVE. ONCE A GENERAL CONTRACTOR IS | | | SELECTED, THE GC WILL ENGAGE THE ROOFING SUB-CONTRACTOR | | | TO PRODUCE SIGNED AND SEALED SHOP DRAWINGS, INCLUDING | | | CALCULATIONS. THE STRUCTURAL ENGINEER WILL REVIEW AND | | | WILL AFFIX THEIR SHOP DRAWING STAMP BEFORE BEING | | | SUBMITTED TO THE BUILDING DEPARTMENT. |
|