| Plan Review Notes For Permit 19061303 |
| Permit Number |
19061303 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-07-16 12:54:58 | FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | | PROTECTIVE DEVICES OR ASSEMBLIES: COLUMN HEADING | | | ?SHUTTER MOUNTING CONNECTION TYPE PER PRODUCT | | | APPROVAL?; USED THE INSTALLATION LEGEND ON PAGE 11 OF | | | THE SUBMITTED PRODUCT APPROVALS AND PROVIDE THE | | | ALPHABETICAL LETTER THAT CORRESPONDS WITH THE | | | INSTALLATION METHODS PROVIDED ON PAGES 6 & 7 FOR THE | | | TOP AND BOTTOM INSTALLATIONS. EXAMPLE: ? HV WALL HEADER | | | INSTALLATION IS THE ONLY ALLOWABLE WALL HEADER | | | INSTALLATION FOR CBS SUBSTRATES. INSTALLATION METHODS | | | D, E, AND F IS ALLOWABLE FOR WALL SILL INSTALLATIONS | | | FOR CBS SUBSTRATES. PLEASE VERIFY ANCHOR SPACINGS; | | | EXAMPLE (M) KEYSTONE MOUNTING INSTALLATION REQUIRES | | | ANCHORS 4? O.C. FOR SPANS LARGER THAN 6?-0? UP TO 8?-0? | | | MAX. |
|