| 2019-07-18 09:06:51 | 1ST REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHOWER DRAINS SHALL HAVE AN OUTLET SIZE OF NOT LESS |
| | THAN 11/2 INCHES IN DIAMETER. PER FBC RES P2708.2 |
| | |
| | 2. THE SHOWER DRAIN SHALL CONNECT TO THE HORIZONTAL WET |
| | VENT PIPING IT SHALL NOT BE SHOWN ABOVE THE LAVATORY ON |
| | THE VERTICAL VENT STACK. PER WPB AMEND TO FBC |
| | 107.3.5.3(12) |
| | |
| | 3. PROVIDE SHOWER PAN DETAIL SHOWING COMPLIANCE WITH |
| | FBC RES P2709 THROUGH P2709.4 |
| | |
| | 4. PROVIDE SIZING CHART FOR TANKLESS HEATER ALSO |
| | PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION |
| | GUIDE. PER WPB AMEND TO FBC 107.2.1 |
| | |
| | 5. THE PLANS SHALL BE DIGITALLY SIGNED BY THE PERSON |
| | RESPONSIBLE FOR DESIGN. PER WPB AMEND TO FBC 107.2.1 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |