Plan Review Notes
Plan Review Notes For Permit 19061126
Permit Number 19061126
Review Stop P
Sequence Number 1
Notes
Date Text
2019-07-18 09:06:511ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHOWER DRAINS SHALL HAVE AN OUTLET SIZE OF NOT LESS
 THAN 11/2 INCHES IN DIAMETER. PER FBC RES P2708.2
  
 2. THE SHOWER DRAIN SHALL CONNECT TO THE HORIZONTAL WET
 VENT PIPING IT SHALL NOT BE SHOWN ABOVE THE LAVATORY ON
 THE VERTICAL VENT STACK. PER WPB AMEND TO FBC
 107.3.5.3(12)
  
 3. PROVIDE SHOWER PAN DETAIL SHOWING COMPLIANCE WITH
 FBC RES P2709 THROUGH P2709.4
  
 4. PROVIDE SIZING CHART FOR TANKLESS HEATER ALSO
 PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION
 GUIDE. PER WPB AMEND TO FBC 107.2.1
  
 5. THE PLANS SHALL BE DIGITALLY SIGNED BY THE PERSON
 RESPONSIBLE FOR DESIGN. PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  