| Plan Review Notes For Permit 19061078 |
| Permit Number |
19061078 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2019-10-22 09:54:57 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 3RD BUILDING REVIEW DENIED: | | | | | | 1A) FAILED: FEMA TECHNICAL BULLETIN 2; THE NEW FINISH | | | FLOOR ELEVATION DETAIL INDICATES 14' 1/4" AT TOP OF | | | SUB-FLOOR. THIS ELEVATION IS NOT ACCEPTABLE DUE TO THE | | | FLOOR FRAMING NOT MEETING THE REQUIREMENTS OF FLOOD | | | DAMAGE-RESISTANT MATERIALS. A NEW ELEVATION CERTIFICATE | | | WILL HAVE TO BE SUBMITTED IF ELEVATIONS ARE ADJUSTED. | | | 1B) FAILED: FBC B 107.2.1 PROVIDE ANCHORING DETAILS FOR | | | THE EXTERIOR A/C RACKS (MEETING 14.00' ELEVATION | | | REQUIREMENT). THE NEW ELEVATION CERTIFICATE (SECTION | | | C2-E) WILL HAVE TO INCLUDE ELEVATION OF EQUIPMENT. | | | 2.) APPROVED. | | | 3.) APPROVED. | | | 4.) APPROVED. | | | 5.) APPROVED. | | | 6.) APPROVED. | | | 7.) APPROVED. | | | 8.) APPROVED. | | | 9.) APPROVED. | | | |
|