| 2019-07-05 16:03:12 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PER GENERAL LIMITATIONS AS NOTED ON PAGE 63 OF 63 OF | | | NOA 15-0709.17 PROVIDE ENHANCED FASTENER DENSITIES PER | | | RAS 117 FOR PERIMETER AND CORNER AREAS. DESIGN | | | PROFESSIONAL SHALL SIGN AND SEAL ENHANCED FASTENER | | | DENSITIES. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
|