| Plan Review Notes For Permit 19060895 |
| Permit Number |
19060895 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2019-07-01 09:11:07 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING PLAN REVIEW DENIED: | | | | | | FBC B R 310.2.1 FAIL; THE REQUIRED CLEAR OPENING WIDTH | | | FOR WINDOW OPENING #17 (BEDROOM) IS TO BE NOT LESS THAN | | | 20". IN THIS LOCATION THE SCHEDULED WINDOW IS FOR A | | | HORIZONTAL SLIDER WITH MEASUREMENTS OF 37" WIDE X | | | 50"HIGH. IT APPEARS THAT THIS WINDOW CAN NOT MEET THE | | | REQUIRED 20" CLEAR OPENING WIDTH. A SINGLE HUNG WINDOW | | | WILL PROBABLY MEET THIS REQUIREMENT. | | | | | | THE SCHEDULED HORIZONTAL SLIDER CAN MEET THE CLEAR | | | OPENING REQUIREMENTS PER FBC EC 702.5 IF THE EXISTING | | | WINDOW AT THIS OPENING (#17) IS A HORIZONTAL SLIDER. | | | PROVIDE PHOTOS FOR VERIFICATION IF THIS IS THE CASE. | | | | | | | | | | | | |
|