2019-06-17 16:13:36GAS 1ST REVIEW**DENIED**
  
 1) A COMPLETE GAS PLAN WITH INSTALLATION MANUALS IS
 REQUIRED FOR A GAS PLAN REVIEW. GENERATOR WILL HAVE A
 STAND ALONE PERMIT.
  
 2) PROVIDE DISTANCE ON PLAN THAT EACH TANKLESS IS FROM
 ANY DOOR OR WINDOW THAT OPENS. FBC 107.3.5
  
 3) PROVIDED R405-2017 ENERGY FORM CALLS OUT TANKLESS
 WATER HEATER AS .60 E.F. THE MIN FEDERAL E.F IS
 CURRENTLY .82. PLEASE REVISE YOUR R405-2017 FORM AND
 RESUBMIT. DOE FEDERAL REGISTER VOL 81, NO 250
  
  
  
  