Plan Review Notes
Plan Review Notes For Permit 19051291
Permit Number 19051291
Review Stop P
Sequence Number 1
Notes
Date Text
2019-06-19 08:37:14CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 30A
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW
 PLUMBING COMMEMTS: DENIED
 1. RE: PLAN SHEET A3; SANITARY PLUMBING RISER DIAGRAM
 A. DRY VENT SERVING THE SHOWER ON THE SECOND FLOOR
 SHALL RISE VERTICALLY FROM THE HORIZONTAL FIXTURE DRAIN
 TO A POINT 6? ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST
 FIXTURE ON THAT FLOOR BEFORE OFFSETTING HORIZONTALLY
 PER FBC RES P3104.3 AND P3104.4.
 B. FIXTURE DRAIN FOR SECOND FLOOR SHOWER SHALL BE
 PROVIDED WITH A WATER SEAL TRAP PER FBC RES P3201.6.
 C. DRY VENT SERVING THE LAVATORY ON THE SECOND FLOOR
 SHALL RISE VERTICALLY TO A POINT 6? ABOVE THE FLOOD
 LEVEL RIM OF THE FIXTURE BEFORE OFFSETTING HORIZONTALLY
 PER FBC RES P3104.4.
 D. THE SANITARY PIPING SERVING THE SECOND FLOOR
 BATHROOM SHALL NOT DISCHARGE THOUGH THE FIRST FLOOR
 BATHROOM GROUP PER FBC RES P3108.1.
 E. DRY VENT SERVING THE TOILET ON THE FIRST FLOOR SHALL
 RISE VERTICALLY FROM THE HORIZONTAL FIXTURE DRAIN TO A
 POINT 6? ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST
 FIXTURE ON THAT FLOOR BEFORE OFFSETTING HORIZONTALLY
 PER FBC RES P3104.3 AND P3104.4.
 F. THE FIXTURE DRAINS FOR THE SHOWER AND THE FLOOR
 DRAIN ON THE FIRST FLOOR SHALL EACH BE PROVIDED WITH A
 WATER SEAL TRAP PER FBC RES P3201.6.
 G. PROVIDE TRAP SEAL PROTECTION FOR THE FIRST FLOOR
 DRAIN PER FBC RES P3201.2.1. SHOW COMPLIANCE USING ONE
 OF THE METHODS DESCRIBED IN FBC RES P3201.2.1.1 THROUGH
 P3201.2.1.4.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19051291 301 PALMETTO ST